The authoritative source for research information and outputs is Elsevier Scopus, with researcher profile verification from the Deanship of Scientific Research.
In this work, the design and experimental validation of passive UHF RFID tag antennas are presented with the objective of evaluating the impact of chip placement and miniaturization approaches on tag performance. Four initial antenna layouts were developed by varying the position of the RFID integrated circuit within a coupling loop. The results show that chip placement directly affects the coupling-loop efficiency, the antenna-chip matching condition, and the practical tolerance of the structure to fabrication-related variations. Simulations and measurements identified Antenna 1 as the best-performing reference configuration, exhibiting the most favorable impedance behavior around 866 MHz and a measured power sensitivity of -16.3 dBm. Based on this reference design, a miniaturized version (Antenna 5) was obtained by integrating meander lines and capacitive end-loading, reducing the physical size while maintaining resonance at 866 MHz. Both structures were fabricated and evaluated using a Voyantic Tagformance measurement system, with read-range measurements performed under free-space conditions and in proximity to dielectric and conductive materials. The results demonstrate a maximum read range of 8.6 m for Antenna 1 in free space, while Antenna 5 preserved a read range of 6.3 m. In the presence of copper, Antenna 1 maintained a read range of 3 m, whereas Antenna 5 achieved approximately 0.5 m, highlighting the trade-off between miniaturization and robustness under conductive loading.
UHF RFID tag antennaflexible antennameandered antennachip placement
Gastrointestinal (GI) tract diseases are among the most common diseases in the world, resulting in more than 8 million deaths. The majority of these deaths occur due to cancer or tumors. Early detection of these tumors can greatly lower the mortality rate. In this work, an implantable multiple-input-multiple-output (MIMO) antenna sensor is constructed for GI tract devices to detect the tumor. The implantable MIMO antenna sensor has two embedded antennas, each operating at 915 MHz. Both elements of the system are placed 0.6 mm apart from each other (edge-to-edge). The volume consumed by this design is measured to be 7 × 7 × 0.25 = 12.25 mm3. It occupies a very small volume due to miniaturization achieved using meandered resonating structures and a high-permittivity substrate. It maintains stable radiation performance (gain = −26.2 dBi at resonance). The antenna units are decoupled by maintaining a proper gap between them and adding a slot on the bottom side. An isolation level greater than 28.7 dB is achieved using these approaches. Since the MIMO system utilizes two antenna elements, its effectiveness is verified using MIMO parameters. At SNR = 20 dB, the channel capacity reaches 8.75 bps/Hz. The proposed antenna ensures high channel capacity and enables seamless communication while simultaneously acting as a sensor to monitor internal changes in the observed region. The frequency response change with variations in the permittivity of human tissue, enabling its sensing capability. Moreover, the antenna sensor maintains stable radiation and S-parameter performance throughout the sensing mechanism. Thus, the proposed solution is suitable for biomedical implants requiring both high-data-rate communication and sensing.
IEEE International Conference on Image Processing, Applications and Systems (IPAS) · 1-8
Skin Cancer is the most serious form of cancer, often spreading to other parts of the body over time. Early and accurate identification of skin lesions can improve the treatment options and increase the probability of curing the disease before it progresses. However, automatic detection of skin cancer faces difficulties because of the imbalanced datasets, affected areas covered by hair or moles, and other visual obstructions. In recent years, Deep Learning (DL) techniques have been widely used to address these challenges. Despite advancements, achieving consistently high accuracy remains difficult. To tackle these challenges, the research proposes a novel hybrid DL model for efficient skin cancer detection from dermoscopic images. The proposed network consists of three key modules: feature extraction using the Xception network, feature enhancement through the Squeeze and Excitation network (SENet), and final classification using a transformer module. This combination of DL models effectively identifies SC. The proposed network is evaluated using benign and malignant dermoscopic images collected from the Kaggle website. Necessary preprocessing steps, such as resizing, grayscale conversion, hair removal, and data balancing, are applied. The proposed network is compared with popular DL networks such as MobileNet, Xception, and VGG-16. The experimental outcome demonstrates that the proposed network outperforms these models, achieving a higher accuracy, recall, precision, and F1 score of 96.83%, 97%, 96.67%, and 96.83%, respectively. The metrics value shows that the proposed network is promising and can be helpful for dermatologists in identifying skin cancer with minimal effort.
skin cancer detectiondermoscopic imageshybrid deep learning modelXception
This study introduces an innovative and compact wearable Long-Range (LoRa) patch antenna developed for monitoring vital signs, with a focus on heart rate and body temperature, in medical applications of Wireless Body Area Networks (WBAN). The antenna functions within the 868 MHz and 915 MHz LoRa bands, filling a notable gap in current literature regarding compact, wearable antennas operating below 1 GHz. Fabricated on a Rogers Duroid RO3003 substrate, the antenna incorporates a U-slot on a conventional rectangular patch, a matching stub, and a partial ground plane to enhance impedance matching and performance efficiency. Furthermore, the antenna displays a bidirectional radiation pattern in the E-plane and an omnidirectional pattern in the H-plane at both frequencies, achieving a peak gain of 2.12 dBi and a radiation efficiency of 99.8% at 868 MHz. The antenna, measuring$80 \times 60 \text {mm}^{2}$($0.23~\lambda _{0} \times 0.17~\lambda _{0}$), was designed, simulated, and optimized using CST Microwave Studio (MWS) software. The performance under bending conditions was also assessed, revealing a bending an excellent efficiency with minimal impact on bandwidth and gain. Specific Absorption Rate (SAR) analysis indicated that all values were within the safety limits set by FCC and ICNIRP standards. Supervised regression machine learning models, specifically the ensemble regression model, were employed to predict resonance frequencies based on various antenna parameters, resulting in an R-squared score of 87.68%. This approach significantly reduced the computational time required for full-wave simulations, streamlining the design process. Real-world experimental validation involved open-field testing of the fabricated prototype for WBAN LoRa applications. The performance, evaluated on a LoRa transceiver system utilizing the LoRa SX1276, demonstrated the superior capabilities of the proposed antenna in heart rate and temperature monitoring, with an average RSSI improvement of -5 dBm at various points within a range of up to 1 km. This confirmed its improved signal transmission and reception capabilities in vital sign monitoring. The proposed antenna shows strong performance metrics and significant potential for WBAN in long-range applications, as evidenced by thorough experimental validations.
LoRawireless body area networksvital signs monitoringheart rate monitoring
International Conference on Smart Electronics and Communication (ICOSEC) · 53-58
In medical field, electronics play a major role in diagnosing diseases. RFID is used to detect diseases, simply by exposing the affected region to the microwave influenced region. Cancer cells are identified to resonate at particular frequencies, which helps the medical society to diagnose malignant tissues. A low profile microstrip antenna operating in UWB band is designed for colon cancer detection. The antenna comprises of fr4 substrate with $16 \times 20 \times 1.67$ mm 3 dimension. An average gain of 3.5 dB is obtained with 97% efficiency. The proposed antenna is a suitable solution for colon cancer detection as It does not require any physical intervention into the human body.
ultra-wideband antennacolon cancer detectionRFIDmicrowave sensing
IEEE International Conference on Advanced Systems and Emergent Technologies (IC_ASET) · 1-6
One of the leading causes of sickness and mortality in the world is colon cancer, which is definitively diagnosed by histological investigation. While both conventional and current approaches may compare images that may cover cancer areas of different kinds after looking at a large number of images of colon cancer, it remains a major cause of cancer-related mortality. Diagnosing benign from malignant disorders to have several complex elements is the primary challenge for colon histopathologists. This is done by applying techniques from image processing and deep learning (DL). The utilisation of whole-slide photography and digital image processing has made it possible to analyse colon cancer using convolutional neural networks. Proficiency in analysis requires accurate classification of colon tumours. In this paper, an improved system for recognising and classifying colon adenocarcinomas by using an adaptive wiener filter to digital histopathology images and a deep convolutional neural network (DCNN) model shows 94.7% accuracy. In the following step, the image is routed to the areas for segmentation using K-means to accurately define the illness's size and shape. Grey level Concurrent Matric (GLCM) is used for feature extraction and by putting this strategy into practice, doctors can create an automated and best method for identifying different types of colon cancer. This work is implemented using MATLAB.
International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME) · 1-8
Optical Coherence Tomography is a noncontact, non-invasive imaging regarded as the best diagnostic approach when compared to other imaging techniques. It provides convenience along with high resolution and is an indispensable tool utilized for the retinal disease diagnosis in clinical practice. Among retinal diseases, the vision loss is very common caused because of deficit or excess of fluid within the retinal layers. High risk for vision loss occurs due to such damages or deformations in the layers of retina. To tackle this, a deep learning approach is opted for diagnosing fluid filled abnormalities in retinal OCT images. The input image is enhanced by means of CLAHE approach and the retinal layer is segmented for the extraction and selection of relevant features. Gabor filter is adopted for the feature extraction and the selected features are further classified by RNN classifier whose parameters are trained by CSO approach. The utilized RNN provides dynamic system modelling and real-time big data classification. The proposed CSO efficiently trains the RNN parameters with increased accuracy and less time complexity .The NEH OCT image dataset is used in MATLAB to validate the proposed approach. The obtained results demonstrate the efficacy of the proposed approach with an accuracy of 95% and reduced processing time of 545.4s.
International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME) · vol. 211 · 1-5
A person who has diabetes mellitus, also called as diabetes and it has a high blood sugar level. The pancreas produces a hormone insulin, which regulates blood glucose levels. Diabetes is brought on by inadequate insulin production. If the issue is not resolved, it can result in heart issues and other catastrophic repercussions. To diagnose diabetes, a variety of invasive methods are available. To obtain the thermal image of the palm for this research, we are using thermal camera as well as near-infrared (NIR) technology. The captured thermal image and the data from the detector was read and processed by the raspberry pi module. The Internet of things (IoT) web page displaying the received data from the sensor system. Anytime that is necessary, the stored data can be retrieved and examined. The created sensor system is side-effect-free, portable, and simple to use.
Stress is common among nursing students and it has been exacerbated during the COVID-19 pandemic. This study examined nursing students' stress levels and their coping strategies in clinical practice before and during the COVID-19 pandemic. A repeated-measures study design was used to examine the relationship between nursing students' stress levels and coping strategies before and during the pandemic. Confirmatory factor analyses were conducted to validate the survey and a student T-test was used to compare the level of stress and coping strategies among 131 nursing students. The STROBE checklist was used. During COVID-19, there was a reliable and accurate relationship between stress and coping strategies. Furthermore, both stress and coping strategy scores were lower before COVID-19 and higher during COVID-19. Nursing students are struggling to achieve a healthy stress-coping strategy during the pandemic. There is a need for the introduction of stress management programs to help foster healthy coping skills. Students are important resources for our health system and society and will continue to be vital long term. It is now up to both nursing educators and health administrators to identify and implement the needed improvements in training and safety measures because they are essential for the health of the patient as well as future pandemics.
nursing studentsstresscoping strategiesclinical practice
Multiple-input multiple-output (MIMO) scheme refers to the technology where more than one antenna is used for transmitting and receiving the information packets. It enhances the channel capacity without more power. The available space in the modern compact devices is limited and MIMO antenna elements need to be placed closely. The closely spaced antennas undergo an undesirable coupling, which deteriorates the antenna parameters. In this paper, an ultra wide-band (UWB) MIMO antenna system with an improved isolation is presented. The system has a wide bandwidth range from 2–13.7 GHz. The antenna elements are closely placed with an edge to edge distance of 3 mm. In addition to the UWB attribute of the system, the mutual coupling between the antennas is reduced by using slotted stub. The isolation is improved and is below −20 dB within the whole operating range. By introducing the decoupling network, the key performance parameters of the antenna are not affected. The system is designed on an inexpensive and easily available FR-4 substrate. To better understand the working of the proposed system, the equivalent circuit model is also presented. To model the proposed system accurately, different radiating modes and inter-mode coupling is considered and modeled. The EM model, circuit model, and the measured results are in good agreement. Different key performance parameters of the system and the antenna element such as envelope correlation coefficient (ECC), diversity gain, channel capcity loss (CCL) gain, radiation patterns, surface currents, and scattering parameters are presented. State-of-the-art comparison with the recent literature shows that the proposed antenna has minimal dimensions, a large bandwidth, an adequate gain value and a high isolation. It is worth noticeable that the proposed antenna has high isolation even the patches has low edge-to-edge gap (3 mm). Based on its good performance and compact dimensions, the proposed antenna is a suitable choice for high throughput compact UWB transceivers.
UWB MIMO antennaantenna isolationmutual coupling reductiondecoupling network