The literature does not provide any "high-performance thin-layer chromatographic (HPTLC)" techniques for the determination of a novel antidiabetic medicine, ertugliflozin (ERZ). Additionally, there are not many environmentally friendly analytical methods for ERZ measurement in the literature. A rapid, sensitive, and eco-friendly reversed-phase-HPTLC (RP-HPTLC) method was designed and validated in an attempt to analyze ERZ in marketed pharmaceutical tablets more precisely, accurately, and sustainably over the traditional normal-phase HPTLC (NP-HPTLC) method. The stationary phases used in the NP- and RP-HPTLC procedures were silica gel 60 NP-18F254S and 60 RP-18F254S plates, respectively. For NP-HPTLC, a chloroform/methanol (85:15 v/v) mobile phase was used. However, ethanol-water (80:20 v/v) was the preferred method for RP-HPTLC. Four distinct methodologies, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREEnness (AGREE) approaches, were used to evaluate the greenness of both procedures. For both approaches, ERZ detection was carried out at 199 nm. Using the NP- and RP-HPTLC techniques, the ERZ measurement was linear in the 50-600 and 25-1200 ng/band ranges. The RP-HPTLC method was found to be more robust, accurate, precise, linear, sensitive, and eco-friendly compared to the NP-HPTLC approach. The results of four greenness tools demonstrated that the RP strategy was greener than the NP strategy and all other reported HPLC techniques. The fact that both techniques can assess ERZ when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 87.41 and 99.28%, respectively, were the assay results for ERZ in commercial tablets when utilizing the NP and RP procedures. Based on several validation and greenness metrics, it was determined that the RP-HPTLC approach was better than the NP-HPTLC method. As a result, it is possible to determine ERZ in pharmaceutical products using the RP-HPTLC approach.
Arabian Journal of Chemistry · مجلد 17 (2) · 105571-105571
The greener “high-performance thin-layer chromatography (HPTLC)” methods for apremilast (APM) analysis in pharmaceutical products and biological fluids are not currently available in the literature. Accordingly, this study involves the development and validation of a rapid, simple, economical, and greener reversed-phase HPTLC methodology for the estimation of APM in prepared nanoparticles (NPs), nanoemulsion, and marketed tablets. The estimation of APM was conducted using “RP-18 silica gel 60 F254S HPTLC plates” as the stationary phase. The combination of ethanol/water (65:35, v/v) was used as the greener mobile phase for APM analysis. The greenness of the method was predicted using three different approaches, namely Analytical Eco-Score (AES), ChlorTox, and the Analytical GREENness (AGREE) approaches. The λmax = 238 nm was used for the APM detection. By contrasting its single band at Rf = 0.61 ± 0.01 with those of pure APM, the HPTLC peaks for APM in an prepared NP formulation, nanoemulsion, and marketed tablets were identified. In the concentration range of 100-700 ng/band, the proposed analytical methodology was linear. The values of AES, ChlorTox, and AGREE were determined to be 95, 0.66 g, and 0.89, respectively, demonstrated an outstanding greener profile for the existing method. The amount of APM in the tablet, NP formulation, nanoemulsion was found to be 98.40, 101.60, and 99.37%, respectively. According to the findings of validation tests and pharmaceutical analysis, the suggested analytical technique could be successfully applied for the routine examination of APM in marketed tablets and laboratory generated nanoformulations.
High-performance thin-layer chromatographic (HPTLC) assays for pomalidomide (PMD) measurement are lacking in the published database. Furthermore, eco-friendly stability-indicating analytical assays for PMD measurement are also lacking in the published database. In order to detect PMD in commercial products more accurately and sustainably than the conventional normal-phase HPTLC (NP-HPTLC) assay, an effort was made to design and verify a sensitive and eco-friendly reversed-phase HPTLC (RP-HPTLC) assay. The silica gel 60 NP-18F254S and 60 RP-18F254S plates were used as the stationary phases for NP-HPTLC and RP-HPTLC methods, respectively. The solvent system for NP-HPTLC was chloroform-methanol (90:10 v/v). However, the solvent system for RP-HPTLC was ethanol-water (75:25 v/v). The greenness scores for both assays were measured by AGREE approach. PMD measurement was performed for both assays at 372 nm. In the 50-600 and 20-1000 ng/band ranges, the NP-HPTLC and RP-HPTLC methods were linear for PMD measurement. The RP-HPTLC assay was superior to the NP-HPTLC method for measuring PMD in terms of sensitivity, accuracy, precision, and robustness. The ability of both methods to identify PMD in the presence of its degradation products suggests that both methods have stability-indicating features. When employing the NP-HPTLC and RP-HPTLC assays, respectively, the assay for PMD in commercial capsules was 88.68 and 98.83%. The AGREE scores for NP-HPTLC and RP-HPTLC assays were calculated to be 0.44 and 0.82, respectively, suggesting an outstanding greenness characteristic of the RP-HPTLC method than the NP-HPTLC method. The RP-HPTLC method was found to be superior to the NP-HPTLC method based on these findings. Therefore, the RP-HPTLC method could be successfully applied for the determination of PMD in pharmaceutical products.
There has been no assessment of the greenness of the described analytical techniques for the simultaneous determination (SMD) of caffeine and paracetamol. As a result, in comparison to the greener normal-phase high-performance thin-layer chromatography (HPTLC) technique, this research was conducted to develop a rapid, sensitive, and greener reversed-phase HPTLC approach for the SMD of caffeine and paracetamol in commercial formulations. The greenness of both techniques was calculated using the AGREE method. For the SMD of caffeine and paracetamol, the greener normal-phase and reversed-phase HPTLC methods were linear in the 50-500 ng/band and 25-800 ng/band ranges, respectively. For the SMD of caffeine and paracetamol, the greener reversed-phase HPTLC approach was more sensitive, accurate, precise, and robust than the greener normal-phase HPTLC technique. For the SMD of caffeine paracetamol in commercial PANEXT and SAFEXT tablets, the greener reversed-phase HPTLC technique was superior to the greener normal-phase HPTLC approach. The AGREE scores for the greener normal-phase and reversed-phase HPTLC approaches were estimated as 0.81 and 0.83, respectively, indicated excellent greenness profiles for both analytical approaches. The greener reversed-phase HPTLC approach is judged superior to the greener normal-phase HPTLC approach based on numerous validation parameters and pharmaceutical assays.
Various analytical approaches for determining β-carotene in vegetable crops and commercial dosage forms have been documented. However, neither the qualitative nor quantitative environmental safety and greener aspects of the literature analytical methodologies of β-carotene analysis have been assessed. As a result, the goal of this research is to develop and validate a reversed-phase “high-performance thin-layer chromatography (HPTLC)” approach for determining β-carotene in traditional (TE) and ultrasound-assisted (UBE) extracts of different fractions of Daucus carota (L.), Ipomea batatas (L.), and commercial formulation. The greener mobile phase for β-carotene analysis was a ternary mixture of ethanol, cyclohexane, and ammonia (95:2.5:2.5, v v v−1). The detection of β-carotene was done at a wavelength of 459 nm. In the 25–1000 ng band−1 range, the greener reversed-phase HPTLC approach was linear. Other validation factors for β-carotene analysis, including as accuracy, precision, robustness, and sensitivity, were likewise dependable. The contents of β-carotene were found to be maximum in hexane: acetone (50:50%) fractions of TE and UBE of D. carota and I. batatas compared to their acetone and hexane fractions. The amount of β-carotene in hexane: acetone (50:50%) portions of TE of D. carota, I. batatas and commercial formulation A was estimated to be 10.32, 3.73, and 6.73 percent w w−1, respectively. However, the amount of β-carotene in hexane: acetone (50:50%) portions of UBE of D. carota, I. batatas and commercial formulation A was estimated to be 11.03, 4.43, and 6.89 percent w w−1, respectively. The greenness scale for the proposed HPTLC strategy was calculated as 0.81 using the “analytical GREEnness (AGREE)” method, indicating that the proposed HPTLC methodology has good greenness. The UBE approach for extracting β-carotene outperformed the TE procedure. These results indicated that the greener reversed-phase HPTLC approach can be utilized for the determination of β-carotene in different vegetable crops, plant-based phytopharmaceuticals, and commercial products. In addition, this approach is also safe and sustainable due to the utilization of a greener mobile phase compared to the toxic mobile phases utilized in literature analytical approaches of β-carotene estimation.
The rapid, highly-sensitive and ecologically greener reversed-phase (RP)/normal-phase (NP) high-performance thin-layer chromatography (HPTLC) densitometric technique has been developed and validated for the determination of trans-resveratrol (TRV). The reversed-phase HPTLC-based analysis of TRV was performed using ethanol–water (65:35, v v−1) combination as the greener mobile phase, while, the normal-phase HPTLC-based estimation of TRV was performed using chloroform–methanol (85:15, v v−1) combination as the routine mobile phase. The TRV detection was carried out at 302 nm for RP/NP densitometric assay. The linearity was recorded as 10–1200 and 30–400 ng band−1 for RP and NP HPTLC techniques, respectively. The RP densitometric assay was observed as highly-sensitive, accurate, precise and robust for TRV detection in comparison with the NP densitometric assay. The contents of TRV in commercial formulation were recorded as 101.21% utilizing the RP densitometric assay, while, the contents of TRV in commercial formulation were found to be 91.64% utilizing the NP densitometric assay. The greener profile of RP/NP technique was obtained using the analytical GREEnness (AGREE) approach. The AGREE scales for RP and NP densitometric assays were estimated 0.75 and 0.48, respectively. The recorded AGREE scale for the RP densitometric assay indicated that this technique was highly green/the ecologically greener compared to the NP densitometric assay. After successful optimization of analytical conditions, validation parameters, AGREE scale and chromatography performance, the RP densitometric assay with univariate calibration was found to be better than the NP densitometric assay for the analysis of TRV.