جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

8 مُخرَج نتائج البحث عن «pharmaceutical analysis»

مقالوصول مفتوح20263استشهاد· Semantic Scholar

Development and Validation of a Robust RP‐HPLC Method for Quantifying Dasatinib in Self‐Microemulsifying Drug Delivery Systems

International Journal of Analytical Chemistry · مجلد 2026 (1) · 4376722-4376722

Dasatinib, a therapy for chronic myeloid leukemia, suffers from poor bioavailability. Self‐microemulsifying drug delivery systems (SMEDDSs) are used to improve its dissolution. This study aimed to develop and validate a novel reverse‐phase high‐performance liquid chromatography (RP‐HPLC) method for quantifying dasatinib in SMEDDS formulations. The RP‐HPLC method utilized a mobile phase of methanol and 0.1% trifluoroacetic acid (55:45, v/v) and identified a peak wavelength for dasatinib at 324 nm. SMEDDS formulations comprised Capryol 90, Transcutol HP, and Tween 40. The method was validated according to ICH guidelines, demonstrating excellent linearity ( R 2 = 0.9993), accuracy (recovery between 98% and 101%), and precision (relative standard deviation of 0.73%). It also showed stability and reliability with limits of detection and quantification of 0.17 and 0.50 µg/mL, respectively. This RP‐HPLC method meets all validation criteria and provides a robust, cost‐effective tool for analyzing dasatinib in SMEDDS formulations.

dasatinibself-microemulsifying drug delivery systemRP-HPLC method developmentmethod validation
مراجعةمفتوح (مستودع)202528استشهاد· Semantic Scholar

Advances in green sample preparation methods for bioanalytical laboratories focusing on drug analysis

Bioanalysis · مجلد 17 (7) · 489-508

Bioanalytical laboratories face significant challenges in sample preparation due to the complexity of biological matrices and the low concentrations of target analytes. This review focuses on advances in green sample preparation (GSP) techniques tailored to meet these challenges while promoting sustainability. Innovations in sorbents, including metal-organic frameworks (MOFs), magnetic nanoparticles (MNPs), sol-gel-based materials, molecularly imprinted polymers (MIPs), carbon-based materials, and natural sorbents like cellulose and kapok fiber, have enhanced extraction efficiency and selectivity. Green solvents such as deep eutectic solvents (DES), ionic liquids (ILs), supramolecular solvents (SUPRAs), and switchable hydrophilicity solvents (SHSs) further reduce environmental impact by minimizing toxic solvent use. This review highlights their use in drug analysis, emphasizing their roles in enhancing extraction efficiency, selectivity, and environmental sustainability. Recent applications demonstrate the integration of these sorbents and solvents into bioanalytical workflows, significantly improving analytical performance while adhering to Green Analytical Chemistry (GAC) principles. It is anticipated that this comprehensive review will aid scholars in the formulation of selective, rapid, environmentally friendly, straightforward, sensitive, and precise analytical methodologies for bioanalysis, thereby promoting innovation and sustainability within drug analysis protocols.

green sample preparationbioanalytical laboratoriespharmaceutical analysissorbents
مقالمفتوح (مستودع)202329استشهاد· Semantic Scholar

A greener RP-HPTLC-densitometry method for the quantification of apremilast in nanoformulations and commercial tablets: Greenness assessment by analytical eco-scale, ChlorTox, and AGREE methods

Arabian Journal of Chemistry · مجلد 17 (2) · 105571-105571

The greener “high-performance thin-layer chromatography (HPTLC)” methods for apremilast (APM) analysis in pharmaceutical products and biological fluids are not currently available in the literature. Accordingly, this study involves the development and validation of a rapid, simple, economical, and greener reversed-phase HPTLC methodology for the estimation of APM in prepared nanoparticles (NPs), nanoemulsion, and marketed tablets. The estimation of APM was conducted using “RP-18 silica gel 60 F254S HPTLC plates” as the stationary phase. The combination of ethanol/water (65:35, v/v) was used as the greener mobile phase for APM analysis. The greenness of the method was predicted using three different approaches, namely Analytical Eco-Score (AES), ChlorTox, and the Analytical GREENness (AGREE) approaches. The λmax = 238 nm was used for the APM detection. By contrasting its single band at Rf = 0.61 ± 0.01 with those of pure APM, the HPTLC peaks for APM in an prepared NP formulation, nanoemulsion, and marketed tablets were identified. In the concentration range of 100-700 ng/band, the proposed analytical methodology was linear. The values of AES, ChlorTox, and AGREE were determined to be 95, 0.66 g, and 0.89, respectively, demonstrated an outstanding greener profile for the existing method. The amount of APM in the tablet, NP formulation, nanoemulsion was found to be 98.40, 101.60, and 99.37%, respectively. According to the findings of validation tests and pharmaceutical analysis, the suggested analytical technique could be successfully applied for the routine examination of APM in marketed tablets and laboratory generated nanoformulations.

apremilastreversed-phase HPTLCgreen analytical chemistrynanoformulations
مقالوصول مفتوح202311استشهاد· Semantic Scholar

A Validated, Stability-Indicating, Eco-Friendly HPTLC Method for the Determination of Cinnarizine

Separations · مجلد 10 (2) · 138-138

The eco-friendly high-performance thin-layer chromatographic (HPTLC) approaches for measuring cinnarizine (CIN) are scant in reported databases. As a result, the current work has developed and validated an eco-friendly HPTLC technique for assessing CIN in commercial formulations. The proposed approach was based the use of ethyl alcohol-water (90:10 v/v) as the eco-friendly mobile phase. A wavelength of 197 nm was used to detect CIN. The greenness score of the current approach was measured using the Analytical GREENness (AGREE) approach. The current approach was linear for CIN measurement in 50–800 ng band−1 range. The current approach for CIN measurement was validated successfully using ICH guidelines and was found to be linear, accurate (% recovery = 99.07–101.29%), precise (% CV = 0.80–0.95%), robust, sensitive (LOD = 16.81 ng band−1 and LOQ = 50.43 ng band−1), specific, selective, stability-indicating, and eco-friendly. The AGREE score for the current approach was calculated to be 0.80, showing an excellent greenness characteristic of the present approach. Under forced degradation conditions, the current approach was successful in separating the CIN degradation product, demonstrating the stability-indicating qualities/selectivity of the present approach. The % assay of CIN in commercial tablet brands A and B was found to be 98.64 and 101.22%, respectively, suggesting the reliability of the present approach in the pharmaceutical analysis of CIN in commercial dosage forms. The obtained findings indicated that CIN in commercial formulations could be routinely determined using the current approach.

cinnarizineHPTLCgreen analytical chemistrystability-indicating assay
مقالوصول مفتوح20239استشهاد· Semantic Scholar

Quantification of Pomalidomide Using Conventional and Eco-Friendly Stability-Indicating HPTLC Assays: A Contrast of Validation Parameters

ACS Omega · مجلد 8 (33) · 30655-30664

High-performance thin-layer chromatographic (HPTLC) assays for pomalidomide (PMD) measurement are lacking in the published database. Furthermore, eco-friendly stability-indicating analytical assays for PMD measurement are also lacking in the published database. In order to detect PMD in commercial products more accurately and sustainably than the conventional normal-phase HPTLC (NP-HPTLC) assay, an effort was made to design and verify a sensitive and eco-friendly reversed-phase HPTLC (RP-HPTLC) assay. The silica gel 60 NP-18F254S and 60 RP-18F254S plates were used as the stationary phases for NP-HPTLC and RP-HPTLC methods, respectively. The solvent system for NP-HPTLC was chloroform-methanol (90:10 v/v). However, the solvent system for RP-HPTLC was ethanol-water (75:25 v/v). The greenness scores for both assays were measured by AGREE approach. PMD measurement was performed for both assays at 372 nm. In the 50-600 and 20-1000 ng/band ranges, the NP-HPTLC and RP-HPTLC methods were linear for PMD measurement. The RP-HPTLC assay was superior to the NP-HPTLC method for measuring PMD in terms of sensitivity, accuracy, precision, and robustness. The ability of both methods to identify PMD in the presence of its degradation products suggests that both methods have stability-indicating features. When employing the NP-HPTLC and RP-HPTLC assays, respectively, the assay for PMD in commercial capsules was 88.68 and 98.83%. The AGREE scores for NP-HPTLC and RP-HPTLC assays were calculated to be 0.44 and 0.82, respectively, suggesting an outstanding greenness characteristic of the RP-HPTLC method than the NP-HPTLC method. The RP-HPTLC method was found to be superior to the NP-HPTLC method based on these findings. Therefore, the RP-HPTLC method could be successfully applied for the determination of PMD in pharmaceutical products.

pomalidomidereversed-phase HPTLCstability-indicating assaygreen analytical chemistry
مقالوصول مفتوح20235استشهاد· Semantic Scholar

Quantification of Suvorexant in Human Urine Using a Validated HPTLC Bioanalytical Method

ACS Omega · مجلد 8 (42) · 39928-39935

High Resolution Image Download MS PowerPoint Slide Suvorexant (SUV) is a new sedative/hypnotic medicine that is recommended to treat insomnia. It is an important medicine from a forensic point of view due to its sedative/hypnotic and depressant effects. To the best of our knowledge, high-performance thin-layer chromatography (HPTLC) bioanalytical methods have not been published to measure SUV in human urine and pharmaceutical samples. Accordingly, this study was designed and validated a sensitive and rapid bioanalytical HPTLC method to determine SUV in human urine samples for the very first time. The densitometric measurement of SUV and the internal standard (IS; sildenafil) was performed on glass-coated silica gel normal-phase-60F254S TLC plates using a mixture of chloroform and methanol (97.5:2.5 v/v) as the eluent system. Both the SUV and IS were detected at a wavelength of 254 nm. Both analytes were extracted using the protein precipitation technique utilizing methanol as the solvent. For the IS and SUV, the R f values were 0.09 and 0.45, respectively. The proposed bioanalytical method for SUV was linear in the 50–1600 ng/band range. The current bioanalytical technique was linear, precise (% RSD = 3.28–4.20), accurate (% recovery = 97.58–103.80), robust (% recovery = 95.31–102.34 and % RSD = 2.81–3.15), rapid, and sensitive (LOD = 3.73 ng/band and LOQ = 11.20 ng/band). These findings suggested that the current bioanalytical method can be regularly used to determine SUV in wide varieties of urine samples.

suvorexanthuman urinepharmaceutical analysissedative-hypnotic drugs
مقالوصول مفتوح20232استشهاد· Semantic Scholar

RP-HPLC-Based Bioanalytical Approach for Simultaneous Quantitation of Cinnarizine and Domperidone in Rat Plasma

Separations · مجلد 10 (3) · 159-159

An accurate, precise and sensitive reverse-phase high-performance liquid chromatography (RP-HPLC) bioanalytical approach was developed for the simultaneous estimation of cinnarizine (CIN) and domperidone (DOM) in rat plasma using irbesartan (IRB) as an internal standard (IS). The proposed RP-HPLC approach was validated as per the latest ICH M10 guidelines. The analytes (CIN and DOM) and IS were extracted from plasma samples using the protein precipitation strategy. Chromatographic separation is accomplished by a C18 SunfireTM (5 µm, 250 mm × 4.6 mm) analytical column, using an isocratic mobile phase consisting of acetonitrile-methanol in 30:70 proportions at a flow rate of 1 mL/min. The detection of all three constituents was recorded at a wavelength of 270 nm with a UV detector. DOM, CIN and IS were eluted at 3.2, 4.5 and 6.1 min, respectively, utilizing a total run time of 10 min. The lower limit of quantification (LLOQ) was 5 ng/mL for CIN and DOM in rat plasma. The proposed RP-HPLC approach was linear in the 5–200 ng/mL range for CIN and DOM. The recovery of the method was greater than 95%, and the relative uncertainty was less than 2%, indicating that the proposed bioanalytical approach was accurate and precise. The limit of detection was established as 1.1 ng/mL for CIN and 1.7 ng/mL for DOM. The created approach was found to be robust and passed all validation criteria; thus, the proposed RP-HPLC approach can be employed successfully for the simultaneous assessment of CIN and DOM in rat plasma.

cinnarizinedomperidonesimultaneous quantitationrat plasma