Bioanalytical laboratories face significant challenges in sample preparation due to the complexity of biological matrices and the low concentrations of target analytes. This review focuses on advances in green sample preparation (GSP) techniques tailored to meet these challenges while promoting sustainability. Innovations in sorbents, including metal-organic frameworks (MOFs), magnetic nanoparticles (MNPs), sol-gel-based materials, molecularly imprinted polymers (MIPs), carbon-based materials, and natural sorbents like cellulose and kapok fiber, have enhanced extraction efficiency and selectivity. Green solvents such as deep eutectic solvents (DES), ionic liquids (ILs), supramolecular solvents (SUPRAs), and switchable hydrophilicity solvents (SHSs) further reduce environmental impact by minimizing toxic solvent use. This review highlights their use in drug analysis, emphasizing their roles in enhancing extraction efficiency, selectivity, and environmental sustainability. Recent applications demonstrate the integration of these sorbents and solvents into bioanalytical workflows, significantly improving analytical performance while adhering to Green Analytical Chemistry (GAC) principles. It is anticipated that this comprehensive review will aid scholars in the formulation of selective, rapid, environmentally friendly, straightforward, sensitive, and precise analytical methodologies for bioanalysis, thereby promoting innovation and sustainability within drug analysis protocols.
green sample preparationbioanalytical laboratoriespharmaceutical analysissorbents
The recent approval of the nasal spray combination of mometasone (MOM) and olopatadine (OLO) presents a significant analytical challenge, as only a single reported method exists for its determination, deviating from eco-friendly practices. This study addresses this critical gap by pioneering the application of machine learning techniques to develop robust UV spectrophotometric approach for the simultaneous quantification of MOM and OLO, along with two genotoxic impurities: 4-dimethylamino pyridine (DAP) and methyl para-toluene sulfonate (MTS). By simultaneously determining these highly concerning genotoxic impurities and active pharmaceutical ingredients, this method underscores its paramount significance in upholding rigorous pharmaceutical quality standards and safeguarding patient safety. Applying the multilevel-multifactor experimental design, the calibration set was meticulously chosen at five different concentrations, yielding 25 calibration mixtures with central levels of 4, 46.5, 2.5, and 3 µg/mL for MOM, OLA, MTS, and DAP, respectively. The key innovation lies in the strategic implementation of the Kennard-Stone Clustering Algorithm to create a robust validation set of thirteen mixtures, resolving the limitations of reported chemometric methods' random data splitting. This approach ensures unbiased evaluation across the full concentration space, improving the method's reliability and sustainability. The robustness of this approach was rigorously tested using five distinct chemometric models: principal component regression, classical least squares, partial least squares, genetic algorithm-partial least squares, and multivariate curve resolution-alternating least squares, demonstrating its broad applicability across diverse modeling techniques. All models successfully determined all components with excellent recovery, low bias-corrected prediction, and adequate limits of detection. The Greenness Index Spider Charts and the Green Solvents Selection Tool were used to choose environmentally conscious solvents. A comprehensive sustainability assessment employed six state-of-the-art tools, including the national environmental method index, complementary green analytical procedure index, analytical greenness metric, blue applicability grade index, carbon footprint analysis, and the red-green-blue 12 metrics. Favorable results across all metrics affirmed the method's eco-friendliness, real-world applicability, and cost-effectiveness, supporting sustainable development goals in pharmaceutical quality control processes.
In the current study, the triazole antifungal terconazole (TRZ) was determined using a novel, extremely sensitive, and environmentally friendly spectrofluorimetric approach. A methanolic solution of TRZ exhibited strong native fluorescence at 373 nm when excited at 241 nm. With a correlation coefficient of 0.9999, a straight-lined calibration curve was produced over the concentration range of 5.0-600.0 ng/mL. With quantification and detection limits of 4.64 and 1.53 ng/mL, respectively, the developed approach showed ultrasensitivity reaching the nanogram scale. Due to its great sensitivity, the method could successfully estimate TRZ in human plasma samples with low %RSD values and high recoveries (98.31-101.66). The method was also effectively used to analyze the TRZ in its vaginal suppositories and creams without interference from existing excipients. With satisfactory results, the method's applicability was expanded to the analysis of TRZ in environmental water samples. Two distinct green metrics, AGSA and MoGAPI, were applied to validate the approach's greenness profile and eco-friendliness. The method's applicability and economic feasibility were also verified using the BAGI tool. According to ICHQ2 (R2) criteria, the proposed approach underwent complete validation. This work introduced the first spectrofluorimetric method for TRZ analysis, enabling its usage in pharmacological, biological, and environmental monitoring.
Arabian Journal of Chemistry · مجلد 17 (4) · 105693-105693
The purpose of this work was to develop and verify a green stability-indicating “high-performance thin-layer chromatographic (HPTLC)” technique to measure risperidone (RISP). The ternary mixture of ethanol, ethyl acetate, and ammonia (70:20:10 v/v/v) was the green mobile phase that was employed. At 281 nm, the detection of RISP was performed. The suggested method's greener profile was produced using the analytical eco-scale (AES), ChlorTox, and analytical GREENness (AGREE) methodologies. It was then contrasted with RISP analysis published HPTLC methods. The proposed methodology for measuring RISP in the 50–1400 ng/band range showed the linearity. Furthermore, the RISP measurement methodology was green, robust, precise (% RSD = 0.80–1.02), sensitive (LOD = 1.86 ng/band and LOQ = 5.60 ng/band), and accurate (% recoveries = 98.23–101.80). The AES, total ChlorTox, and AGREE scales for the suggested technique were found to be 83, 1.26 g, and 0.75, indicating an excellent greener profile. The current methodology's AES and total ChlorTox were significantly higher than those of previously published HPTLC RISP analysis methods. RISP was found to be highly stable under acid, base, and thermal stress conditions, while it was found to be most unstable under oxidative degradation conditions. Additionally, the stability-indicating aspect of the suggested technique was able to identify RISP in the presence of its degradation products. It was discovered that commercial tablet brands A and B had 98.12 and 99.62 % of RISP, respectively. The results of this investigation suggested that RISP in commercial formulations might be regularly analyzed utilizing the suggested green technology.
Recently, the U.S. Food and Drug Administration (FDA) approved combined dosage forms of lesinurad (LND) and allopurinol (ALU) in fixed-dose combinations to treat hyperuricemia associated with gout. For the simultaneous estimation (SME) of LND and ALU, neither conventional “high-performance thin-layer chromatography (HPTLC)” nor a greener HPTLC approach has been published to date. This study was carried out to design and validate a rapid, sensitive, and greener normal-phase HPTLC technique for the SME of LND and ALU in FDA-approved fixed-dose combination tablets. Ethyl acetate, ethanol, and water in a ternary ratio of 70:20:10 (v/v/v) were employed as a greener eluent system for the SME of LND and ALU. Normal-phase silica gel 60F254S plates were employed as the stationary phase. At a wavelength of 240 nm, LND and ALU were simultaneously estimated. The current method’s greenness was assessed using the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREENness (AGREE) methodologies. The current method was linear in the 30–1200 ng/band range for LND and ALU. The current approach was extensively validated and demonstrated to be accurate, precise, robust, sensitive, and greener for the SME of LND and ALU. The results of all greenness tools, including NEMI, AES (89), ChlorTox (0.96 g), and AGREE (0.81) showed that the current approach had an exceptional greener profile. Using the present methodology, the amounts of LND in FDA-approved fixed-dose combinations A and B were measured to be 98.73 and 99.17%, respectively. Using the present methodology, the amounts of ALU in FDA-approved fixed-dose combinations A and B were determined to be 99.27 and 100.58%, respectively. These data support the applicability of the current methodology for SME of LND and ALU in FDA-approved products. The findings of this study suggested that the current approach may be consistently applied to measure the LND and ALU in FDA-approved products.
The literature does not provide any "high-performance thin-layer chromatographic (HPTLC)" techniques for the determination of a novel antidiabetic medicine, ertugliflozin (ERZ). Additionally, there are not many environmentally friendly analytical methods for ERZ measurement in the literature. A rapid, sensitive, and eco-friendly reversed-phase-HPTLC (RP-HPTLC) method was designed and validated in an attempt to analyze ERZ in marketed pharmaceutical tablets more precisely, accurately, and sustainably over the traditional normal-phase HPTLC (NP-HPTLC) method. The stationary phases used in the NP- and RP-HPTLC procedures were silica gel 60 NP-18F254S and 60 RP-18F254S plates, respectively. For NP-HPTLC, a chloroform/methanol (85:15 v/v) mobile phase was used. However, ethanol-water (80:20 v/v) was the preferred method for RP-HPTLC. Four distinct methodologies, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREEnness (AGREE) approaches, were used to evaluate the greenness of both procedures. For both approaches, ERZ detection was carried out at 199 nm. Using the NP- and RP-HPTLC techniques, the ERZ measurement was linear in the 50-600 and 25-1200 ng/band ranges. The RP-HPTLC method was found to be more robust, accurate, precise, linear, sensitive, and eco-friendly compared to the NP-HPTLC approach. The results of four greenness tools demonstrated that the RP strategy was greener than the NP strategy and all other reported HPLC techniques. The fact that both techniques can assess ERZ when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 87.41 and 99.28%, respectively, were the assay results for ERZ in commercial tablets when utilizing the NP and RP procedures. Based on several validation and greenness metrics, it was determined that the RP-HPTLC approach was better than the NP-HPTLC method. As a result, it is possible to determine ERZ in pharmaceutical products using the RP-HPTLC approach.
Abstract So far, no documented method for simultaneously analyzing lesinurad (LND) and febuxostat (FBX) has been reported for either traditional high-performance thin-layer chromatography (HPTLC) or a green HPTLC technique. In order to determine LND and FBX simultaneously in commercially available fixed-dose combo tablets, this study devised a normal-phase HPTLC method that is fast, sensitive, and green. The green eluents for the simultaneous analysis of LND and FBX were a mixture of ethyl acetate:ethanol:water at 70:20:10 (v/v/v) ratio. The new approach’s greenness was predicted utilizing four distinct greenness tools: the National Environmental Method Index, Analytical Eco-Scale, ChlorTox, and Analytical GREENness approaches, and the results revealed a significantly greener profile. The current method operated on a linear scale between 30 and 1,000 ng·band −1 . It was confirmed that the current approach is sensitive, accurate, precise, robust, and green. The LND and FBX contents of commercially available tablet products A and B were found to be within the range of 100 ± 2%, indicating that the existing methodology for simultaneously determining LND and FBX in pharmaceutical combination products is applicable. The results of the current methodology indicated that LND and FBX could be consistently measured in pharmaceutical combination products simultaneously using the current approach.
Abstract The objective of the proposed investigation is the development and validation of a green stability-indicating reverse-phase high-performance thin-layer chromatographic method to determine croconazole hydrochloride (CCZ). The developing system used was an 80:20 v/v mixture of acetone and water. The measurement of CCZ was done at 198 nm. With the use of the Analytical Eco-Scale (AES), ChlorTox, and Analytical GREEnness (AGREE) tools, greenness was evaluated. The linearity was demonstrated by the present method in the 25–1,200 ng/band range. The present approach was additionally reliable, accurate, sensitive, precise, and green. An exceptional greenness profile was demonstrated by the AES, total ChlorTox, and AGREE scales, which were determined to be 89, 1.08 g, and 0.82, respectively. The greenness metrics of the present method were much better than the reported high-performance liquid chromatography approach. Under acid and oxidative degradation circumstances, CCZ was shown to be unstable, while under alkaline and thermal-stress settings, it was sufficiently stable. Furthermore, the stability-indicating component determined by analytical method identified CCZ in the presence of its degradation products. Commercial CCZ cream was found to contain 0.98% w/w of CCZ. The investigation’s results suggested that CCZ in commercially available creams might be regularly examined with the help of the recommended green technology.
Arabian Journal of Chemistry · مجلد 17 (7) · 105837-105837
There are very limited analytical procedures to determine lemborexant (LMB) in dosage forms and biological materials. However, the literature does not provide any “high-performance thin-layer chromatographic (HPTLC)” assays to determine LMB. In an effort to analyze LMB in commercial pharmaceutical tablets more precisely, accurately, and sustainably than with the normal-phase-HPTLC (NP-HPTLC) approach, a sensitive and greener reverse-phase-HPTLC (RP-HPTLC) method was developed and validated. For NP-HPTLC, an acetone-petroleum ether (40:60 v/v) developing system was used. However, ethanol–water (85:15 v/v) was the developing system for RP-HPTLC. Four different techniques, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREENness (AGREE), were used to evaluate the greenness of both procedures. LMB measurement was linear in the 50–500 and 20–1000 ng/band ranges, respectively for NP and RP procedures. RP procedure was more robust (uncertainties = 0.90–0.95 %), accurate (recoveries = 98.24–101.57 %), precise (uncertainties = 0.87–1.00 %), linear (20–1000 ng/band), sensitive (LOD = 0.92 ng/band and LOQ = 2.76 ng/band), and greener over NP procedure. The results of greenness assessment using NEMI (all four circles green), AES (93), ChlorTox (0.88 g), and AGREE (0.89) demonstrated that the RP strategy was greener than NP strategy and all other reported HPLC methods. The fact that both techniques can assess LMB when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 89.24 % and 98.79 %, respectively, were the assay results for LMB in pharmaceutical tablets when utilizing the NP and RP procedures. Based on all validation and greenness metrics, it was found that RP procedure was better than the NP procedure. As a result, it is possible to assess LMB in pharmaceutical products using RP procedure.
Arabian Journal of Chemistry · مجلد 17 (2) · 105571-105571
The greener “high-performance thin-layer chromatography (HPTLC)” methods for apremilast (APM) analysis in pharmaceutical products and biological fluids are not currently available in the literature. Accordingly, this study involves the development and validation of a rapid, simple, economical, and greener reversed-phase HPTLC methodology for the estimation of APM in prepared nanoparticles (NPs), nanoemulsion, and marketed tablets. The estimation of APM was conducted using “RP-18 silica gel 60 F254S HPTLC plates” as the stationary phase. The combination of ethanol/water (65:35, v/v) was used as the greener mobile phase for APM analysis. The greenness of the method was predicted using three different approaches, namely Analytical Eco-Score (AES), ChlorTox, and the Analytical GREENness (AGREE) approaches. The λmax = 238 nm was used for the APM detection. By contrasting its single band at Rf = 0.61 ± 0.01 with those of pure APM, the HPTLC peaks for APM in an prepared NP formulation, nanoemulsion, and marketed tablets were identified. In the concentration range of 100-700 ng/band, the proposed analytical methodology was linear. The values of AES, ChlorTox, and AGREE were determined to be 95, 0.66 g, and 0.89, respectively, demonstrated an outstanding greener profile for the existing method. The amount of APM in the tablet, NP formulation, nanoemulsion was found to be 98.40, 101.60, and 99.37%, respectively. According to the findings of validation tests and pharmaceutical analysis, the suggested analytical technique could be successfully applied for the routine examination of APM in marketed tablets and laboratory generated nanoformulations.
The eco-friendly high-performance thin-layer chromatographic (HPTLC) approaches for measuring cinnarizine (CIN) are scant in reported databases. As a result, the current work has developed and validated an eco-friendly HPTLC technique for assessing CIN in commercial formulations. The proposed approach was based the use of ethyl alcohol-water (90:10 v/v) as the eco-friendly mobile phase. A wavelength of 197 nm was used to detect CIN. The greenness score of the current approach was measured using the Analytical GREENness (AGREE) approach. The current approach was linear for CIN measurement in 50–800 ng band−1 range. The current approach for CIN measurement was validated successfully using ICH guidelines and was found to be linear, accurate (% recovery = 99.07–101.29%), precise (% CV = 0.80–0.95%), robust, sensitive (LOD = 16.81 ng band−1 and LOQ = 50.43 ng band−1), specific, selective, stability-indicating, and eco-friendly. The AGREE score for the current approach was calculated to be 0.80, showing an excellent greenness characteristic of the present approach. Under forced degradation conditions, the current approach was successful in separating the CIN degradation product, demonstrating the stability-indicating qualities/selectivity of the present approach. The % assay of CIN in commercial tablet brands A and B was found to be 98.64 and 101.22%, respectively, suggesting the reliability of the present approach in the pharmaceutical analysis of CIN in commercial dosage forms. The obtained findings indicated that CIN in commercial formulations could be routinely determined using the current approach.
High-performance thin-layer chromatographic (HPTLC) assays for pomalidomide (PMD) measurement are lacking in the published database. Furthermore, eco-friendly stability-indicating analytical assays for PMD measurement are also lacking in the published database. In order to detect PMD in commercial products more accurately and sustainably than the conventional normal-phase HPTLC (NP-HPTLC) assay, an effort was made to design and verify a sensitive and eco-friendly reversed-phase HPTLC (RP-HPTLC) assay. The silica gel 60 NP-18F254S and 60 RP-18F254S plates were used as the stationary phases for NP-HPTLC and RP-HPTLC methods, respectively. The solvent system for NP-HPTLC was chloroform-methanol (90:10 v/v). However, the solvent system for RP-HPTLC was ethanol-water (75:25 v/v). The greenness scores for both assays were measured by AGREE approach. PMD measurement was performed for both assays at 372 nm. In the 50-600 and 20-1000 ng/band ranges, the NP-HPTLC and RP-HPTLC methods were linear for PMD measurement. The RP-HPTLC assay was superior to the NP-HPTLC method for measuring PMD in terms of sensitivity, accuracy, precision, and robustness. The ability of both methods to identify PMD in the presence of its degradation products suggests that both methods have stability-indicating features. When employing the NP-HPTLC and RP-HPTLC assays, respectively, the assay for PMD in commercial capsules was 88.68 and 98.83%. The AGREE scores for NP-HPTLC and RP-HPTLC assays were calculated to be 0.44 and 0.82, respectively, suggesting an outstanding greenness characteristic of the RP-HPTLC method than the NP-HPTLC method. The RP-HPTLC method was found to be superior to the NP-HPTLC method based on these findings. Therefore, the RP-HPTLC method could be successfully applied for the determination of PMD in pharmaceutical products.