Advanced Health Science and Technology Journal · مجلد 2 (1) · 97-103
Abstract Background: Artificial intelligence (AI), particularly large language models (LLMs), is increasingly used in medical education and examination preparation. Recent studies suggest that frontier LLMs may have reached near-ceiling performance on standardized medical benchmarks; however, less is known about whether such performance converges across models and whether shared reasoning vulnerabilities persist, particularly in clinically complex domains such as Alzheimer’s disease. Aims and Objectives: This study aimed to evaluate the performance of three frontier LLMs—ChatGPT-4 (OpenAI), Gemini 2.5 Flash (Google), and Claude Sonnet 4 (Anthropic)—on Alzheimer’s disease-related multiple-choice questions drawn from international medical licensing examinations. A secondary objective was to assess the guideline alignment of model explanations to identify differences in reasoning quality beyond accuracy. Materials and Methods: A total of 49 Alzheimer’s disease-focused multiple-choice questions were curated from peer-reviewed preparatory resources and represented five international examinations: USMLE, SMLE, MCCQE, IFOM, and PNA. Each model answered all questions under standardized, independent conditions. Accuracy was recorded, and explanations were evaluated using a guideline alignment score (0–1) based on consistency with authoritative clinical guidelines (NICE, WHO, and AAN). Interrater reliability was assessed using Cohen’s kappa. Results: All three models achieved identical overall accuracy of 98% (48/49 correct). Each model made the same diagnostic error on a single USMLE vignette, misclassifying Alzheimer’s disease as normal pressure hydrocephalus, revealing a shared reasoning blind spot. Accuracy was uniform across clinical domains, except for diagnosis (94.1%). Guideline alignment scores differed modestly, with Claude Sonnet 4 demonstrating the highest alignment (0.95), followed by ChatGPT-4 (0.92) and Gemini 2.5 Flash (0.88). Conclusion: Frontier LLMs demonstrate performance convergence on structured Alzheimer’s disease examination questions, achieving near-identical accuracy. However, convergence also extends to shared diagnostic errors, highlighting systematic reasoning vulnerabilities. Incorporating guideline alignment reveals meaningful differences in explanatory quality despite similar accuracy. These findings underscore the importance of evaluating not only correctness but also reasoning quality and guideline fidelity when integrating LLMs into medical education and clinical decision support.
large language modelsAlzheimer's diseasemedical licensing examinationsmultiple-choice questions
Current Medical Imaging Formerly Current Medical Imaging Reviews · مجلد 21 · e15734056391923-e15734056391923
INTRODUCTION: Accurate interpretation of medical images is vital for diagnosis and treatment planning. However, noise in medical imaging significantly hampers this process, leading to potential diagnostic errors. Traditional denoising techniques often require large datasets or compromise diagnostic details. METHOD: This study proposes a Distribution-based Compressed Denoising Scheme (DCDS) leveraging transfer learning to enhance diagnostic precision. The framework analyzes pixel distributions to distinguish normal and noisy pixels using incremental and decremental distribution verification. A chest CT scan dataset with Gaussian-like noise was used to train the model, employing correlation mapping between training and target images for effective variance estimation. RESULT: Experimental analysis showed that DCDS significantly improves noise reduction, variance detection, and diagnostic precision. The peak signal-tonoise ratio improved across all evaluated ranges (24-32 dB), with a noise reduction rate exceeding 82% in optimal conditions. DCDS reduced mean error and analysis time, enhancing overall system efficiency. Transfer learning allowed for effective pixel classification and noise prediction with fewer data and computational resources. DISCUSSION: Compared to existing denoising methods, DCDS offers better generalization through statistical modeling and knowledge-sharing between training and learning states. However, current validation is limited to CT imaging with Gaussian noise. Broader modality testing and integration of perceptual and clinical grading metrics are needed. CONCLUSION: The DCDS framework presents a promising, lightweight, adaptive, and accurate solution for medical image denoising. It holds potential for realtime diagnostic support, but further optimization and clinical validation are necessary to ensure generalizability across diverse imaging modalities and noise types.
medical image denoisingtransfer learningchest CTGaussian noise
Background and Objectives Hand and wrist fractures are among the most frequently encountered injuries in emergency departments and are often misdiagnosed, particularly when interpreted by non-specialist clinicians. These diagnostic errors can lead to treatment delays and long-term complications. Artificial intelligence (AI), particularly deep learning algorithms, is emerging as a promising adjunct to improve diagnostic accuracy in radiographic fracture detection. This study aims to evaluate the effectiveness of Artificial Intelligence (AI) in detecting hand and wrist fractures compared to manual radiographic interpretation by clinicians. Materials and Methods A systematic review and meta-analysis were conducted to assess the diagnostic performance of AI models in detecting hand and wrist fractures compared to conventional radiographic interpretation by clinicians. A comprehensive search of PubMed, Google Scholar, Science Direct, and Wiley Online Library was performed. Eligible studies included those utilizing AI for fracture detection with sensitivity and specificity data. Pooled estimates were calculated using fixed- and random-effects models. Heterogeneity was assessed via I 2 statistics, and publication bias was examined using funnel plots and Egger’s test. Results Eighteen studies met inclusion criteria. The pooled sensitivity and specificity under the random-effects model were 0.910 and 0.912, respectively, indicating high diagnostic accuracy of AI models. However, substantial heterogeneity (I 2 = 99.09% for sensitivity; 96.43% for specificity) and publication bias were observed, likely due to variations in AI algorithms, sample sizes, and study designs. Conclusions Most AI models demonstrated good diagnostic accuracy, with high sensitivity and specificity scores (≥90%). However, some models fell short in sensitivity and specificity (≤90%), indicating performance variations across different AI models or algorithms. From a clinical perspective, AI models with lower sensitivity scores may fail to detect hand and wrist fractures, potentially delaying treatment, while those with lower specificity scores could lead to unnecessary interventions—treating hands and wrists that are not fractured.
hand fractureswrist fracturesartificial intelligencedeep learning
Advanced Health Science and Technology Journal · مجلد 1 (2) · 92-99
Abstract Background: Epilepsy remains one of the most prevalent neurological disorders worldwide, characterized by recurrent seizures resulting from abnormal electrical brain activity. Traditional diagnostic methods, such as electroencephalography (EEG) and magnetic resonance imaging (MRI), although widely used, often fail to provide sufficient accuracy when applied in isolation due to their inherent limitations in temporal or spatial resolution. These challenges highlight the need for integrated analytical approaches capable of leveraging complementary modalities for improved diagnostic precision. Objectives: This study aims to address the limitations of single-modality diagnostic techniques by proposing a multimodal deep learning framework that integrates EEG and MRI data to enhance the accuracy of epilepsy detection. The objectives include preprocessing EEG signals to remove artifacts, segmenting MRI scans for structural feature extraction, employing CNNs to model EEG spatio-temporal dependencies, using ViTs to capture hierarchical MRI features, and integrating these representations through a cross-attention fusion mechanism for effective supervised classification. Method: The methodology involves preprocessing EEG signals to eliminate artifacts and ensure clean temporal representation, along with MRI scan segmentation to extract structural information. Convolutional neural networks (CNNs) were used to model spatio-temporal patterns within EEG signals, while vision transformers (ViTs) extracted spatially hierarchical features from MRI data. A cross-attention fusion mechanism was designed to integrate these complementary modalities, and a supervised classifier performed the final prediction. Model training and evaluation were carried out using a high-performance computing setup with GPU acceleration to efficiently handle multimodal data. Results: Experimental results demonstrated that the proposed multimodal deep learning model significantly outperformed state-of-the-art pretrained CNN and ViT baselines across major evaluation metrics, including accuracy, precision, recall, F1-score, and Matthews correlation coefficient. The confusion matrix further confirmed robust differentiation between normal and epileptic classes, emphasizing the reliability of the proposed framework for accurate clinical decision-making. Conclusion: The findings of this study indicate that integrating EEG and MRI data through a multimodal fusion framework provides a substantial improvement in epilepsy detection compared to single-modality approaches. The results highlight the importance of combining complementary temporal and structural information to achieve reliable diagnostic performance. This work contributes to advancing early detection, reducing diagnostic errors, and supporting timely treatment strategies, reinforcing the value of multimodal deep learning approaches in personalized healthcare.
OBJECTIVE: To study the prevalence and nature of stroke mimics (SM) among Saudi patients who came to the emergency department with a sudden neurological deficit and suspected stroke. METHODS: The electronic health records from February 2016 to July 2018 of patients who were admitted to the Stroke Unit at King Abdulaziz Medical City, Ministry of National Guard Health Affairs, Riyadh, Kingdom of Saudi Arabia (KAMC-RD) with a suspected stroke were all reviewed. A comparison between SM and stroke was established. Our study identified the predictors of SM by using logistic regression analysis. This study was approved by the local institutional review board. RESULTS: Out of 1,063 patients, 131 (12.3%) had SM. The most common causes were a peripheral vestibular disorder (27.4%) followed by psychogenic causes (24.4%). Stroke mimics were more common among younger individuals and women. Arterial hypertension, diabetes, and smoking were less likely to be found in SMs. At discharge, individuals with SM were more likely to be independent, had milder deficits, and shorter hospital stays. Predictors of SM were young age, female gender, mild deficit at presentation, and good functional status before the stroke. CONCLUSION: The incidence of stroke mimics is common among suspected stroke patients. Practicing physicians should consider potential diagnostic errors, particularly in the hyperacute phase of the stroke.