Arabian Journal of Chemistry · مجلد 17 (4) · 105693-105693
The purpose of this work was to develop and verify a green stability-indicating “high-performance thin-layer chromatographic (HPTLC)” technique to measure risperidone (RISP). The ternary mixture of ethanol, ethyl acetate, and ammonia (70:20:10 v/v/v) was the green mobile phase that was employed. At 281 nm, the detection of RISP was performed. The suggested method's greener profile was produced using the analytical eco-scale (AES), ChlorTox, and analytical GREENness (AGREE) methodologies. It was then contrasted with RISP analysis published HPTLC methods. The proposed methodology for measuring RISP in the 50–1400 ng/band range showed the linearity. Furthermore, the RISP measurement methodology was green, robust, precise (% RSD = 0.80–1.02), sensitive (LOD = 1.86 ng/band and LOQ = 5.60 ng/band), and accurate (% recoveries = 98.23–101.80). The AES, total ChlorTox, and AGREE scales for the suggested technique were found to be 83, 1.26 g, and 0.75, indicating an excellent greener profile. The current methodology's AES and total ChlorTox were significantly higher than those of previously published HPTLC RISP analysis methods. RISP was found to be highly stable under acid, base, and thermal stress conditions, while it was found to be most unstable under oxidative degradation conditions. Additionally, the stability-indicating aspect of the suggested technique was able to identify RISP in the presence of its degradation products. It was discovered that commercial tablet brands A and B had 98.12 and 99.62 % of RISP, respectively. The results of this investigation suggested that RISP in commercial formulations might be regularly analyzed utilizing the suggested green technology.
The literature does not provide any "high-performance thin-layer chromatographic (HPTLC)" techniques for the determination of a novel antidiabetic medicine, ertugliflozin (ERZ). Additionally, there are not many environmentally friendly analytical methods for ERZ measurement in the literature. A rapid, sensitive, and eco-friendly reversed-phase-HPTLC (RP-HPTLC) method was designed and validated in an attempt to analyze ERZ in marketed pharmaceutical tablets more precisely, accurately, and sustainably over the traditional normal-phase HPTLC (NP-HPTLC) method. The stationary phases used in the NP- and RP-HPTLC procedures were silica gel 60 NP-18F254S and 60 RP-18F254S plates, respectively. For NP-HPTLC, a chloroform/methanol (85:15 v/v) mobile phase was used. However, ethanol-water (80:20 v/v) was the preferred method for RP-HPTLC. Four distinct methodologies, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREEnness (AGREE) approaches, were used to evaluate the greenness of both procedures. For both approaches, ERZ detection was carried out at 199 nm. Using the NP- and RP-HPTLC techniques, the ERZ measurement was linear in the 50-600 and 25-1200 ng/band ranges. The RP-HPTLC method was found to be more robust, accurate, precise, linear, sensitive, and eco-friendly compared to the NP-HPTLC approach. The results of four greenness tools demonstrated that the RP strategy was greener than the NP strategy and all other reported HPLC techniques. The fact that both techniques can assess ERZ when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 87.41 and 99.28%, respectively, were the assay results for ERZ in commercial tablets when utilizing the NP and RP procedures. Based on several validation and greenness metrics, it was determined that the RP-HPTLC approach was better than the NP-HPTLC method. As a result, it is possible to determine ERZ in pharmaceutical products using the RP-HPTLC approach.
Abstract The objective of the proposed investigation is the development and validation of a green stability-indicating reverse-phase high-performance thin-layer chromatographic method to determine croconazole hydrochloride (CCZ). The developing system used was an 80:20 v/v mixture of acetone and water. The measurement of CCZ was done at 198 nm. With the use of the Analytical Eco-Scale (AES), ChlorTox, and Analytical GREEnness (AGREE) tools, greenness was evaluated. The linearity was demonstrated by the present method in the 25–1,200 ng/band range. The present approach was additionally reliable, accurate, sensitive, precise, and green. An exceptional greenness profile was demonstrated by the AES, total ChlorTox, and AGREE scales, which were determined to be 89, 1.08 g, and 0.82, respectively. The greenness metrics of the present method were much better than the reported high-performance liquid chromatography approach. Under acid and oxidative degradation circumstances, CCZ was shown to be unstable, while under alkaline and thermal-stress settings, it was sufficiently stable. Furthermore, the stability-indicating component determined by analytical method identified CCZ in the presence of its degradation products. Commercial CCZ cream was found to contain 0.98% w/w of CCZ. The investigation’s results suggested that CCZ in commercially available creams might be regularly examined with the help of the recommended green technology.
Toxicology Research · مجلد 13 (3) · tfae071-tfae071
Abstract Astaxanthin (ASX), a red pigment belonging to carotenoids, has antioxidant activity and anti-oxidative stress effect. Atrazine (ATZ), a frequently used herbicide, whose degradation products are the cause for nephrosis and other oxidative stress associated diseases. This study was aimed to reveal the potential protective mechanism of astaxanthin against atrazine-induced nephrosis. Atrazine was orally given (250 mg/kg bw) to the mice along with astaxanthin (100 mg/kg bw) for 28 days. Serum biochemical indicators, oxidative stress biomarkers, ATPase activities, ion concentration, histomorphology, and various renal genes expression linked with apoptosis, Nrf2 signaling pathway, and aquaporins (AQPs) were assessed. It was found that serum creatinine (SCr), blood urea nitrogen (BUN), and MDA levels were significantly increased after the treatment of atrazine, whereas serum renal oxidative stress indicators like CAT, GSH, T-AOC, SOD decreased. Renal histopathology showed that atrazine significantly damaged renal tissues. The activities of Ca 2+-Mg 2+-ATPase were increased whereas Na +-K +-ATPase decreased significantly (P < 0.05). Moreover, results confirmed that the expression of AQPs, Nrf2, and apoptosis genes were also altered after atrazine administration. Interestingly, astaxanthin supplementation significantly (P < 0.05) improved atrazine-induced nephrotoxicity via decreasing SCr, BUN, oxidative stress, ionic homeostasis and reversing the changes in AQPs, Nrf2, and apoptosis gene expression. These findings collectively suggested that astaxanthin has strong potential ameliorative impact against atrazine induced nephrotoxicity.
Arabian Journal of Chemistry · مجلد 17 (7) · 105837-105837
There are very limited analytical procedures to determine lemborexant (LMB) in dosage forms and biological materials. However, the literature does not provide any “high-performance thin-layer chromatographic (HPTLC)” assays to determine LMB. In an effort to analyze LMB in commercial pharmaceutical tablets more precisely, accurately, and sustainably than with the normal-phase-HPTLC (NP-HPTLC) approach, a sensitive and greener reverse-phase-HPTLC (RP-HPTLC) method was developed and validated. For NP-HPTLC, an acetone-petroleum ether (40:60 v/v) developing system was used. However, ethanol–water (85:15 v/v) was the developing system for RP-HPTLC. Four different techniques, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREENness (AGREE), were used to evaluate the greenness of both procedures. LMB measurement was linear in the 50–500 and 20–1000 ng/band ranges, respectively for NP and RP procedures. RP procedure was more robust (uncertainties = 0.90–0.95 %), accurate (recoveries = 98.24–101.57 %), precise (uncertainties = 0.87–1.00 %), linear (20–1000 ng/band), sensitive (LOD = 0.92 ng/band and LOQ = 2.76 ng/band), and greener over NP procedure. The results of greenness assessment using NEMI (all four circles green), AES (93), ChlorTox (0.88 g), and AGREE (0.89) demonstrated that the RP strategy was greener than NP strategy and all other reported HPLC methods. The fact that both techniques can assess LMB when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 89.24 % and 98.79 %, respectively, were the assay results for LMB in pharmaceutical tablets when utilizing the NP and RP procedures. Based on all validation and greenness metrics, it was found that RP procedure was better than the NP procedure. As a result, it is possible to assess LMB in pharmaceutical products using RP procedure.
High-performance thin-layer chromatographic (HPTLC) assays for pomalidomide (PMD) measurement are lacking in the published database. Furthermore, eco-friendly stability-indicating analytical assays for PMD measurement are also lacking in the published database. In order to detect PMD in commercial products more accurately and sustainably than the conventional normal-phase HPTLC (NP-HPTLC) assay, an effort was made to design and verify a sensitive and eco-friendly reversed-phase HPTLC (RP-HPTLC) assay. The silica gel 60 NP-18F254S and 60 RP-18F254S plates were used as the stationary phases for NP-HPTLC and RP-HPTLC methods, respectively. The solvent system for NP-HPTLC was chloroform-methanol (90:10 v/v). However, the solvent system for RP-HPTLC was ethanol-water (75:25 v/v). The greenness scores for both assays were measured by AGREE approach. PMD measurement was performed for both assays at 372 nm. In the 50-600 and 20-1000 ng/band ranges, the NP-HPTLC and RP-HPTLC methods were linear for PMD measurement. The RP-HPTLC assay was superior to the NP-HPTLC method for measuring PMD in terms of sensitivity, accuracy, precision, and robustness. The ability of both methods to identify PMD in the presence of its degradation products suggests that both methods have stability-indicating features. When employing the NP-HPTLC and RP-HPTLC assays, respectively, the assay for PMD in commercial capsules was 88.68 and 98.83%. The AGREE scores for NP-HPTLC and RP-HPTLC assays were calculated to be 0.44 and 0.82, respectively, suggesting an outstanding greenness characteristic of the RP-HPTLC method than the NP-HPTLC method. The RP-HPTLC method was found to be superior to the NP-HPTLC method based on these findings. Therefore, the RP-HPTLC method could be successfully applied for the determination of PMD in pharmaceutical products.
The literature on ecofriendly/greener high-performance thin-layer chromatographic (HPTLC) methods for quantifying flufenamic acid (FFA) is scant. In order to develop and validate a stability-indicating greener HPTLC densitometry assay for FFA determination in marketed products, this research was conducted. The ecofriendly eluent system was composed of ethanol–water (70:30 v/v). FFA was measured at 290 nm of wavelength. The greenness scale of suggested analytical assay was derived using “Analytical GREENness (AGREE)” methodology. The suggested stability-indicating HPTLC assay was linear for FFA determination in 25–1400 ng/band range with a determination coefficient of 0.9974. The suggested analytical assay for FFA analysis was simple, rapid, accurate, precise, robust, selective, stability-indicating, and greener. The AGREE scale for the developed stability-indicating HPTLC assay was derived to be 0.77 utilizing AGREE methodology, indicating an outstanding greenness characteristic of the suggested densitometry technique. The ecofriendly HPTLC technique was able to detect FFA degradation product under forced degradation studies, indicating its stability-indication characteristics and selectivity. The amount of FFA in marketed tablets brand A and B was determined to be 101.28 and 99.17%, respectively, indicating the suitability of the suggested analytical technique in the assay of FFA in marketed products. These results indicated that FFA in marketed products may be routinely measured using the stability-indicating greener HPTLC technique.
Despite the fact that several analytical methodologies have been reported for the determination of curcumin (CCM) in a wide range of sample matrices, the greener liquid chromatographic approaches to determine CCM are scarce in the literature. Therefore, this research is designed to develop and validate a greener stability-indicating “high-performance liquid chromatography (HPLC)” methodology to determine CCM in an in-house developed nanoemulsion, Curcuma longa L. extract, and commercial tablets. CCM was measured on a Nucleodur (150 mm × 4.6 mm) RP C18 column with 5 µm-sized particles. Ethanol and ethyl acetate (83:17 v/v) made up the greener eluent system, which was pumped at a flow speed of 1.0 mL/min. At a wavelength of 425 nm, CCM was detected. The greener HPLC methodology was linear in the 1–100 µg/mL range, with a determination coefficient of 0.9983. The greener HPLC methodology for CCM estimation was also rapid (Rt = 3.57 min), accurate (%recoveries = 98.90–101.85), precise (%CV = 0.90–1.11), and sensitive (LOD = 0.39 µg/mL and LOQ = 1.17 µg/mL). The AGREE approach predicted the AGREE score of 0.81 for the established HPLC technique, indicating an outstanding greenness profile. The utility of the greener HPLC methodology was demonstrated by determining CCM in the in-house developed nanoemulsion, Curcuma longa extract, and commercial tablets. The % amount of CCM in the in-house developed nanoemulsion, Curcuma longa extract, and commercial tablets was found to be 101.24%, 81.15%, and 78.41%, respectively. The greener HPLC methodology was able to detect its degradation product under various stress conditions, suggesting its stability-indication characteristics. These results suggested that CCM in developed nanoemulsion, plant extract samples, and commercial tablets may be routinely determined using the greener HPLC methodology.
A wide range of analytical techniques have been reported to determine cordycepin (CDN) in various sample matrices. Nevertheless, greener analytical approaches for CDN estimation are scarce in the literature. As a result, this study was designed to develop and validate a stability-indicating greener “high-performance thin-layer chromatography (HPTLC)” technique for CDN determination in a laboratory-developed formulation. The greener eluent system for CDN detection was ethanol–water (75:25 v/v). At a wavelength of 262 nm, CDN was measured. The greenness scale of the proposed analytical technology was derived using the “Analytical GREENness (AGREE)” approach. The proposed stability-indicating HPTLC assay was linear for CDN analysis in the 50–1000 ng/band range with a determination coefficient of 0.9978. The proposed analytical technique for CDN analysis was simple, rapid, accurate, precise, robust, selective, stability-indicating, and greener. The AGREE score for the proposed stability-indicating HPTLC technique was calculated to be 0.79 using the AGREE calculator. The current protocol was able to detect CDN degradation products under various stress conditions, indicating its stability-indication characteristics and selectivity. The AGREE quantitative score indicated that the stability-indicating current protocol had outstanding greener characteristics. The amount of CDN in the laboratory-developed formulation was determined to be 98.84%, indicating the suitability of the current protocol in the assay of CDN in the formulations. These results suggested that CDN in a laboratory-developed formulation may be regularly determined using the stability-indicating greener HPTLC strategy.
Combination therapy of many anthelmintic drugs has been used to achieve fast animal curing. Q-DRENCH is an oral suspension, containing four different active drugs against GIT worms in sheep, commonly used in Australia and New Zeeland. The anti-parasitic drugs are Albendazole (ALB), Levamisole HCl (LEV), Abamectin (ABA), and Closantel (CLO). The main purpose of this study is to present a new simultaneous stability-indicting HPLC-DAD method for the analysis of the four drugs. The recommended liquid system was 1 mL of Triethylamine/L water, adjusting the pH to 3.5 by glacial acetic acid: acetonitrile solvent (20:80, v/v). Isocratic elusion achieved the desired results of separation at a 2 mL/min flow rate using Zorbax C-18 as a stationary phase. Detection was performed at 210 nm. The linearity ranges were 15.15 to 93.75 μg/mL for ALB, 25 to 150 μg/mL for LEV, 30 to 150 μg/mL for ABA, and 11.7 to 140.63 μg/mL for CLO. Moreover, the final greenness score was 0.62 using the AGREE tool, which reflects the eco-friendly nature. Moreover, the four drugs were determined successfully in the presence of their stressful degradation products. This work presents the first chromatographic method for simultaneous analysis for Q-DRENCH oral suspension drugs in the presence of their stressful degradation products.
The study aimed to develop a new reverse-phase high-performance liquid chromatography (RP-HPLC) method with diode array detection (DAD) detection for simultaneous estimation of escitalopram (EST) and clonazepam (CZP) in tablet dosage forms with a quality by design (QbD) approach. The chromatographic conditions were optimized by Box-Behnken design (BBD) and developed method was validated for the linearity, system suitability, accuracy, precision, robustness, sensitivity, and solution stability according to International Council for Harmonization (ICH) guidelines. EST and CZP standard drugs peaks were separated at retention times of 2.668 and 5.046 min by C-18 column with dimension of 4.6 × 100 mm length and particle size packing 2.5 µm. The mobile phase was methanol: 0.1% orthophosphoric acid (OPA) (25:75, v/v), with a flow rate of 0.7 mL/min at temperature of 26 °C. The sample volume injected was 20 µL and peaks were detected at 239 nm. Using the standard calibration curve, the % assay of marketed tablet was founded 98.89 and 98.76 for EST and CZP, respectively. The proposed RP-HPLC method was able to detect EST and CZP in the presence of their degradation products, indicating the stability-indicating property of the developed RP-HPLC method. The validation parameter’s results in terms of linearity, system suitability, accuracy, precision, robustness, sensitivity, and solution stability were in an acceptable range as per the ICH guidelines. The newly developed RP-HPLC method with QbD application is simple, accurate, time-saving, and economic.
“High-performance thin-layer chromatography (HPTLC)” methods for gefitinib (GFT) estimation are scarce in the literature. In addition, greener analytical techniques for GFT estimation are also lacking in the literature. Accordingly, an attempt was undertaken to invent and validate a sensitive and greener normal-phase HPTLC method for GFT analysis in commercial tablets in comparison to the routine normal-phase HPTLC method. The greenness index for both methods was assessed using “Analytical GREENness (AGREE)” methodology. GFT detection was carried out using both methods at 332.0 nm. In the 30–700 ng/band and 20–1400 ng/band ranges, the routine and greener HPTLC assays were linear for GFT estimation. The greener HPTLC method was highly sensitive, more accurate, more precise, and more robust than the routine HPTLC assay for GFT estimation. Both methods were able to detect GFT in the presence of its degradation products, suggesting the stability-indicating property of both methods. The assay of GFT in commercial tablets was 92.45% and 99.74% using the routine and greener HPTLC assays, respectively. The AGREE index for routine and greener analytical assays was predicted to be 0.44 and 0.77, respectively, indicating the excellent greenness index of the greener HPTLC assay over the routine HPTLC assay. The greener HPTLC assay is considered superior to the routine HPTLC assay based on these results.
Despite various reported analytical methods for topiramate (TPM) analysis, greener analytical approaches are scarce in literature. As a consequence, the objective of the current research is to design a normal-phase stability-indicating high-performance thin-layer chromatography (SI-HPTLC) methodology for TPM analysis in marketed tablet dosage forms that is rapid, sensitive, and greener. TPM was derivatized densitometrically and analyzed at 423 nm in visible mode with anisaldehyde-sulfuric acid as the derivatizing agent. The greener SI-HPTLC technique was linear in the 30–1200 ng band−1 range. In addition, the suggested SI-HPTLC methodology for TPM analysis was simple, rapid, cheaper, precise, robust, sensitive, and environmentally friendly. The greener SI-HPTLC method was able to detect TPM along with its degradation products under acid, base, and oxidative degradation conditions. However, no TPM degradation was recorded under thermal and photolytic stress conditions. TPM contents in commercial tablet dosage forms were recorded as 99.14%. Using 12 different principles of green analytical chemistry, the overall analytical GREEnness (AGREE) score for the greener SI-HPTLC method was calculated to be 0.76, confirming the proposed normal-phase SI-HPTLC method’s good greener nature. Overall, these results demonstrated that the suggested SI-HPTLC technique for TPM measurement in pharmaceutical products was reliable and selective.