Almaarefa University
The authoritative source for research information and outputs is Elsevier Scopus, with researcher profile verification from the Deanship of Scientific Research.

المخرجات

Research outputs

Articles, reviews, conference papers and book chapters, indexed by DOI and linked to University researchers.

ArticleOpen access2026

Global thermodynamic consistency: A linear-algebraic diagnostic framework

Results in Engineering · vol. 32 · 112122-112122

Thermodynamic cycle models are routinely assembled from heterogeneous sources – steam-table lookups, manufacturer data sheets, handbook correlations, and hand-computed preliminary estimates – and an error introduced in any one source (a misread enthalpy, a sign error in a heat balance, a wrong coefficient-of-performance value) can propagate silently through every downstream calculation. Engineers currently guard against this by checking governing equations pairwise, but pairwise checking has a structural blind spot: a set of equations can pass every pairwise comparison and still be globally infeasible as a system. We develop a linear-algebraic diagnostic framework that closes this gap. The governing equations of a steady-state thermodynamic cycle – energy balances over turbines, compressors, boilers, condensers, and expansion devices, together with isentropic-process relations and the coefficient-of-performance definition – form a linear system A x = b whose state vector x collects enthalpies, heat transfer rates, and work quantities at each process node. We show that global inconsistency of this system is equivalent to infeasibility of A x = b , and that infeasibility is always witnessed by a vector in the left nullspace of A that is not orthogonal to b – an algebraically certifiable condition we call a nullspace inconsistency certificate , computable from a single thin SVD and fundamentally inaccessible to pairwise checking. Building on this certificate, we prove that pairwise consistency checks are provably insufficient to detect global thermodynamic inconsistency; we establish existence and uniqueness of a minimum-norm repair vector that returns the right-hand-side data to the nearest feasible point on the constraint manifold; we derive equation-localization weights that rank which governing equation is the primary source of a fault; and we construct a differentiable repair operator whose fixed points correspond to globally self-consistent cycle models. The complete detection-localization-repair pipeline runs in O ( kn 2 ) time via a thin SVD – negligible overhead for cycle models of practical size – and requires no information beyond the equations and data an engineer already has on hand. We demonstrate the framework on the Rankine steam-power cycle and the vapor-compression refrigeration cycle, where it correctly detects, localizes, and corrects hidden inconsistencies – including a 50 kJ kg − 1 enthalpy error in Rankine cycle steam tables and a simultaneous condenser-balance fault with an erroneous COP value in the refrigeration cycle – that pass all pairwise equation checks yet render the global model infeasible. We further discuss how the certificate behaves under measurement and property-estimation uncertainty, and compare the approach against residual-based checking, data-reconciliation, and optimization-based fault detection. The framework requires only the linear (or linearized) governing equations and standard property data already used in routine cycle calculations, making it directly deployable as an auditing layer in existing engineering workflows.

thermodynamic consistencylinear algebradiagnostic frameworkenergy balance
ArticleOpen access20258citation· Semantic Scholar

Heat recovery unit integrated with biomass gasification for producing hydrogen/power/heat using a novel cascaded ORC with biphenyl/diphenyl oxide mixture; ML optimization and economic evaluation

Case Studies in Thermal Engineering · vol. 76 · 107397-107397

This work provides a detailed evaluation of a novel biomass-fueled multigeneration system, conceived to contribute to the growing emphasis on sustainable energy solutions. The architecture comprises a biomass gasifier, an innovative cascaded organic Rankine cycle (CORC) incorporating a high-temperature mixture in the top cycle, a proton exchange membrane electrolyzer (PEME), a Brayton cycle, and waste heat utilization units, all operating together to deliver electricity, hydrogen (H 2 ), and thermal output. A comprehensive thermodynamic modeling framework is established to evaluate the system’s performance across various operational scenarios. The framework emphasizes critical metrics, including exergy efficiency, levelized total emissions (LTE), and payback period (PP). These indicators ensure a holistic assessment of energy, exergy, economic, and environmental considerations. Parametric studies demonstrate that enhancements in biomass mass flow rate and combustion chamber temperature significantly increase power output and H 2 production while reducing the payback period, underscoring the system’s flexibility and economic feasibility. Furthermore, the study employs sophisticated machine learning optimization methods, combining artificial neural networks (ANNs) with genetic algorithms (GA), to determine optimal operating conditions with minimal computational effort and maximum efficiency. When evaluated at nominal parameters, the system records an exergy efficiency of 23.72%, achieves a PP of 5.61 years, and yields an LTE value of 0.34 ton/GJ. However, under optimized conditions, these values improve to 35.01%, 3.78 years, and 0.241 ton/GJ, respectively.

biomass gasificationhydrogen productionpolygenerationproton exchange membrane electrolyzer
ArticleOpen access20254citation· Semantic Scholar

Deep learning and smart energy-based lightweight urban power load forecasting model for sustainable urban growth

Frontiers in Sustainable Cities · vol. 6

Introduction Urban power load forecasting is essential for smart grid planning but is hindered by data imbalance issues. Traditional single-model approaches fail to address this effectively, while multi-model methods mitigate imbalance by splitting datasets but incur high costs and risk losing shared power distribution characteristics. Methods A lightweight urban power load forecasting model (DLUPLF) is proposed, enhancing LSTM networks with contrastive loss in short-term sampling, a difference compensation mechanism, and a shared feature extraction layer to reduce costs. The model adjusts predictions by learning distribution differences and employs dynamic class-center contrastive learning loss for regularization. Its performance was evaluated through parameter tuning and comparative analysis. Results The DLUPLF model demonstrated improved accuracy in forecasting imbalanced datasets while reducing computational costs. It preserved shared power distribution characteristics and outperformed traditional and multi-model approaches in efficiency and prediction accuracy. Discussion DLUPLF effectively addresses data imbalance and model complexity challenges, making it a promising solution for urban power load forecasting. Future work will focus on real-time applications and broader smart grid systems.

short-term load forecastingclass imbalancecontrastive learninglightweight neural networks
ArticleOpen access20252citation· Semantic Scholar

Leveraging advanced waste heat recovery techniques and dynamic interplay of operational parameters in maximizing efficiency of next-gen hybrid thermal systems; Numerical computational modeling

Case Studies in Thermal Engineering · vol. 75 · 107084-107084

This study focuses on waste energy recovery and environmental protection through the evaluation of an integrated clean energy system combining compressed air energy storage, a solid oxide fuel cell, and a heat recovery unit. Designed to sustainably generate power, heat, and compressed air, the system's performance is assessed from energy, exergy, and environmental perspectives. Results show that recovering waste energy by optimizing current density significantly boosts outputs, power increases from 95.46 kW to 165.8 kW, heat recovery improves from 195.6 kW to 483 kW, and compressed air generation rises from 278.8 g/s to 535.6 g/s. However, higher current density also raises electrical emissions (from 850 to 1142 kg/MWh) and cycle emissions (from 278.8 to 291.8 kg/MWh), despite a reduction in thermal emissions (from 414.9 to 392 kg/MWh), underscoring the environmental trade-offs involved. The system demonstrated energy efficiencies ranging from 60.31% to 63.85% and exergy efficiencies between 27.5% and 32.87%, depending on operating conditions. Furthermore, elevated temperatures and utilization rates negatively affect both energy and exergy efficiencies, with improved efficiencies observed at lower current densities and temperatures. These insights emphasize the importance of balancing operational parameters to maximize waste energy recovery while minimizing environmental impacts, contributing to the advancement of sustainable and efficient hybrid clean energy technologies.

waste heat recoverycompressed air energy storagesolid oxide fuel cellsheat recovery units