جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

3 مُخرَج نتائج البحث عن «transfer learning»

مقالمفتوح (مستودع)20251استشهاد· Semantic Scholar

Enhancing Diagnostic Precision: A Distribution-Based Compressed Denoising Scheme using Transfer Learning for Noise Reduction in Medical Imaging

Current Medical Imaging Formerly Current Medical Imaging Reviews · مجلد 21 · e15734056391923-e15734056391923

INTRODUCTION: Accurate interpretation of medical images is vital for diagnosis and treatment planning. However, noise in medical imaging significantly hampers this process, leading to potential diagnostic errors. Traditional denoising techniques often require large datasets or compromise diagnostic details. METHOD: This study proposes a Distribution-based Compressed Denoising Scheme (DCDS) leveraging transfer learning to enhance diagnostic precision. The framework analyzes pixel distributions to distinguish normal and noisy pixels using incremental and decremental distribution verification. A chest CT scan dataset with Gaussian-like noise was used to train the model, employing correlation mapping between training and target images for effective variance estimation. RESULT: Experimental analysis showed that DCDS significantly improves noise reduction, variance detection, and diagnostic precision. The peak signal-tonoise ratio improved across all evaluated ranges (24-32 dB), with a noise reduction rate exceeding 82% in optimal conditions. DCDS reduced mean error and analysis time, enhancing overall system efficiency. Transfer learning allowed for effective pixel classification and noise prediction with fewer data and computational resources. DISCUSSION: Compared to existing denoising methods, DCDS offers better generalization through statistical modeling and knowledge-sharing between training and learning states. However, current validation is limited to CT imaging with Gaussian noise. Broader modality testing and integration of perceptual and clinical grading metrics are needed. CONCLUSION: The DCDS framework presents a promising, lightweight, adaptive, and accurate solution for medical image denoising. It holds potential for realtime diagnostic support, but further optimization and clinical validation are necessary to ensure generalizability across diverse imaging modalities and noise types.

medical image denoisingtransfer learningchest CTGaussian noise
مقالوصول مغلق2025

Accelerating Prostate Cancer Detection Through Histopathological Image Analysis Using Artificial Intelligence

Microscopy Research and Technique · مجلد 89 (5) · 687-704

Prostate cancer is a prevalent and serious health concern, ranking among the most frequently diagnosed cancers and a leading cause of cancer-related deaths in men worldwide. Early detection and accurate diagnosis are crucial for improving patient outcomes by limiting disease progression. Histopathological image analysis remains the gold standard for prostate cancer detection; however, manual interpretation is time-consuming and requires specialized expertise. To address these challenges, this study proposes a hybrid deep learning framework that combines an ensemble of transfer-learned CNNs (VGG-16, DenseNet-121, and AlexNet) with a fine-tuned Vision Transformer (ViT). The CNN ensemble extracts rich local features, while the ViT captures global contextual dependencies through a self-attention mechanism and a multilayer perceptron (MLP). Additionally, a cross-attention fusion (CAF) module integrates local and global features, and knowledge distillation (KD) enables a lightweight student network suitable for efficient clinical deployment. The study utilizes the publicly available PANDA dataset for training and testing. Preprocessing steps, including patch generation, gamma correction, and stain deconvolution, enhance image quality and feature representation. A comprehensive evaluation was conducted using standard performance metrics such as accuracy, true positive rate (TPR), true negative rate (TNR), precision, F1-score, false negative rate (FNR), and false positive rate (FPR). An ablation study confirmed the contribution of each module, highlighting the critical role of ensemble CNNs, CAF, and ViT in improving performance. Experimental results demonstrate that the proposed model outperforms conventional transfer learning models and existing state-of-the-art techniques, achieving 97.91% accuracy, along with significant improvements in TPR, TNR, and reduced FNR/FPR. The computational complexity, evaluated in terms of parameters, FLOPs, GPU memory, and inference time, indicates that the proposed model is more demanding than traditional CNNs. Nevertheless, the architecture strikes a practical balance between predictive accuracy and efficiency, making it suitable for real-world clinical applications. These findings underscore the potential of AI-powered hybrid models in expediting prostate cancer diagnosis and enabling timely intervention for improved patient outcomes.

prostate cancer detectionhistopathology image analysishybrid CNN-ViT modelcross-attention fusion