جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

7 مُخرَج نتائج البحث عن «tablets»

مقالوصول مغلق202414استشهاد· Semantic Scholar

Simultaneous Estimation of Lesinurad and Allopurinol in the New FDA-Approved Products Using a Greener Normal-Phase HPTLC Method: Greenness Assessment Using the NEMI, Analytical Eco-Score, ChlorTox, and AGREE Methods

ACS Sustainable Chemistry & Engineering · مجلد 12 (4) · 1526-1535

Recently, the U.S. Food and Drug Administration (FDA) approved combined dosage forms of lesinurad (LND) and allopurinol (ALU) in fixed-dose combinations to treat hyperuricemia associated with gout. For the simultaneous estimation (SME) of LND and ALU, neither conventional “high-performance thin-layer chromatography (HPTLC)” nor a greener HPTLC approach has been published to date. This study was carried out to design and validate a rapid, sensitive, and greener normal-phase HPTLC technique for the SME of LND and ALU in FDA-approved fixed-dose combination tablets. Ethyl acetate, ethanol, and water in a ternary ratio of 70:20:10 (v/v/v) were employed as a greener eluent system for the SME of LND and ALU. Normal-phase silica gel 60F254S plates were employed as the stationary phase. At a wavelength of 240 nm, LND and ALU were simultaneously estimated. The current method’s greenness was assessed using the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREENness (AGREE) methodologies. The current method was linear in the 30–1200 ng/band range for LND and ALU. The current approach was extensively validated and demonstrated to be accurate, precise, robust, sensitive, and greener for the SME of LND and ALU. The results of all greenness tools, including NEMI, AES (89), ChlorTox (0.96 g), and AGREE (0.81) showed that the current approach had an exceptional greener profile. Using the present methodology, the amounts of LND in FDA-approved fixed-dose combinations A and B were measured to be 98.73 and 99.17%, respectively. Using the present methodology, the amounts of ALU in FDA-approved fixed-dose combinations A and B were determined to be 99.27 and 100.58%, respectively. These data support the applicability of the current methodology for SME of LND and ALU in FDA-approved products. The findings of this study suggested that the current approach may be consistently applied to measure the LND and ALU in FDA-approved products.

lesinuradallopurinolsimultaneous estimationfixed-dose combination tablets
مقالوصول مفتوح202411استشهاد· Semantic Scholar

Comparing the Greenness and Validation Metrics of Traditional and Eco-Friendly Stability-Indicating HPTLC Methods for Ertugliflozin Determination

ACS Omega · مجلد 9 (21) · 23001-23012

The literature does not provide any "high-performance thin-layer chromatographic (HPTLC)" techniques for the determination of a novel antidiabetic medicine, ertugliflozin (ERZ). Additionally, there are not many environmentally friendly analytical methods for ERZ measurement in the literature. A rapid, sensitive, and eco-friendly reversed-phase-HPTLC (RP-HPTLC) method was designed and validated in an attempt to analyze ERZ in marketed pharmaceutical tablets more precisely, accurately, and sustainably over the traditional normal-phase HPTLC (NP-HPTLC) method. The stationary phases used in the NP- and RP-HPTLC procedures were silica gel 60 NP-18F254S and 60 RP-18F254S plates, respectively. For NP-HPTLC, a chloroform/methanol (85:15 v/v) mobile phase was used. However, ethanol-water (80:20 v/v) was the preferred method for RP-HPTLC. Four distinct methodologies, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREEnness (AGREE) approaches, were used to evaluate the greenness of both procedures. For both approaches, ERZ detection was carried out at 199 nm. Using the NP- and RP-HPTLC techniques, the ERZ measurement was linear in the 50-600 and 25-1200 ng/band ranges. The RP-HPTLC method was found to be more robust, accurate, precise, linear, sensitive, and eco-friendly compared to the NP-HPTLC approach. The results of four greenness tools demonstrated that the RP strategy was greener than the NP strategy and all other reported HPLC techniques. The fact that both techniques can assess ERZ when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 87.41 and 99.28%, respectively, were the assay results for ERZ in commercial tablets when utilizing the NP and RP procedures. Based on several validation and greenness metrics, it was determined that the RP-HPTLC approach was better than the NP-HPTLC method. As a result, it is possible to determine ERZ in pharmaceutical products using the RP-HPTLC approach.

ertugliflozinreversed-phase HPTLCgreen analytical chemistrymethod validation
مقالوصول مفتوح20249استشهاد· Semantic Scholar

Simultaneous estimation of ibuprofen, caffeine, and paracetamol in commercial products using a green reverse-phase HPTLC method

Green Processing and Synthesis · مجلد 13 (1)

Abstract A fast, sensitive, and green reverse-phase “high-performance thin-layer chromatography” approach for the simultaneous estimation of ibuprofen (IBF), caffeine (CAF), and paracetamol (PCM) in marketed formulations was established and verified in this study. The binary combination of acetone and water (80:20 v/v) was used as the green eluent system. The current method’s greenness was predicted using four different approaches, namely National Environmental Method Index, Analytical Eco-Score (89), ChlorTox (1.08 g), and the Analytical GREENness (83) approaches, which demonstrated an outstanding greener profile. The present approach was linear in the range of 25–800 ng·band −1 for the simultaneous estimation of IBF, CAF, and PCM. In addition, the current method was accurate (% recoveries = 100 ± 2), precise (%CV < 2%), robust (%CV < 2), sensitive (LOD = 1.13–2.71 ng·band −1 and LOQ = 3.39–8.10 ng·band −1 ), and green. The amount of IBF, CAF, and PCM in commercial tablets was determined to be 99.51%, 98.25%, and 100.64%, respectively. The present method for the simultaneous determination of IBF, CAF, and PCM in marketed tablets is supported by these data. The findings of this study suggested that the current approach may be consistently applied to analyze IBF, CAF, and PCM in marketed tablets.

ibuprofencaffeineparacetamolsimultaneous estimation
مقالوصول مفتوح20247استشهاد· Semantic Scholar

Utilization of Waste Eggshell Powder as an Excipient for Vitamin D3 Tablet Preparation

ACS Omega · مجلد 9 (3) · 3980-3987

Keeping in mind the health scenario in Kingdom of Saudi Arabia with respect to vitamin D3 (VD3) deficiency and its significant role in calcium homeostasis and human metabolism, this research is exploring the combination of eggshell (as a source of calcium) and VD3 as a very economical solution for this problem. Eggshells from local restaurant were collected, washed, ground, sieved, and characterized by Fourier transforms infrared spectroscopy (FTIR), scanning electron microscopy (SEM), differential scanning calorimetry (DSC), X-ray diffraction (XRD), and Brunauer-Emmett-Teller (BET) techniques. The results of FTIR, SEM, DSC, XRD, and BET indicate that eggshell powder (ESP) was properly processed. Directly compressed tablets containing 2.5 mg of VD3 (equivalent to 50,000 IU), that are based on the use of ESP as tablet filler, were manufactured based on mixing Avicel PH 101 with ESP in different ratios (9:1, 1:1, and 1:9) in addition to the use of both Avicel PH 101 and ESP alone as tablet filler. Tablets properties were evaluated according to USP30-NF25 pharmacopoeia tests in terms of weight variation test, drug content uniformity, tablet hardness, tablet friability, tablet disintegration, and in vitro dissolution profile. The VD3 contents were found to be 98.77-102.35% in all formulations. After 90 min of study, all formulations showed in vitro drug release content in the range of 99.29-101.05%. All of the tested parameters of ESP tablets were similar to those of commercial Avicel PH 101. All of the tested properties of tablets with ESP as a filler were found to be within the acceptable limits of the pharmacopeia recommendations. Therefore, ESP could be exploited for its use as a filler in direct compression tablets.

eggshell powdervitamin D3tablet excipientsdirect compression
مقالوصول مفتوح20247استشهاد· Semantic Scholar

Simultaneous determination of lesinurad and febuxostat in commercial fixed-dose combinations using a greener normal-phase HPTLC method

Green Processing and Synthesis · مجلد 13 (1)

Abstract So far, no documented method for simultaneously analyzing lesinurad (LND) and febuxostat (FBX) has been reported for either traditional high-performance thin-layer chromatography (HPTLC) or a green HPTLC technique. In order to determine LND and FBX simultaneously in commercially available fixed-dose combo tablets, this study devised a normal-phase HPTLC method that is fast, sensitive, and green. The green eluents for the simultaneous analysis of LND and FBX were a mixture of ethyl acetate:ethanol:water at 70:20:10 (v/v/v) ratio. The new approach’s greenness was predicted utilizing four distinct greenness tools: the National Environmental Method Index, Analytical Eco-Scale, ChlorTox, and Analytical GREENness approaches, and the results revealed a significantly greener profile. The current method operated on a linear scale between 30 and 1,000 ng·band −1 . It was confirmed that the current approach is sensitive, accurate, precise, robust, and green. The LND and FBX contents of commercially available tablet products A and B were found to be within the range of 100 ± 2%, indicating that the existing methodology for simultaneously determining LND and FBX in pharmaceutical combination products is applicable. The results of the current methodology indicated that LND and FBX could be consistently measured in pharmaceutical combination products simultaneously using the current approach.

lesinuradfebuxostatfixed-dose combination tabletssimultaneous determination
مقالمفتوح (مستودع)20244استشهاد· Semantic Scholar

Consumption of aphrodisiac drugs without prescription among men in Saudi Arabia: cross-sectional study

Saudi Pharmaceutical Journal · مجلد 32 (2) · 101955-101955

The prevalence and patterns of aphrodisiac drug consumption without prescription among men in Saudi Arabia remain underexplored, with limited empirical evidence available. Given the potential health implications and societal considerations, a comprehensive investigation is warranted. Aim: Assess the Prevalence, pattern of use and the associated factors of Aphrodisiac drugs consumption without prescription among Men at Najran City, Saudi Arabia. Methods: Employing a cross-sectional descriptive study, 500 participants were included through convenience sampling. The utilized questionnaires covered a range of data, including socio-demographic information, patterns of aphrodisiac use, knowledge about aphrodisiacs, lifestyle details, a sexual health inventory for men, and a perceived stress level scale. Results: The study reveals a significant prevalence of unsanctioned aphrodisiac drug use (31%) among men in Najran City, Saudi Arabia, with a majority (79.3%) consuming these substances four times monthly. Associated disparities in knowledge, lifestyle, stress, and sexual function underscore the urgent need for policy interventions and tailored health education initiatives for this demographic.. Conclusion: Approximately one-third of the sampled population engaged in the unsanctioned use of aphrodisiac drugs, with the majority utilizing them four times monthly. Tablets emerged as the most prevalent form of consumption. Commonly cited motives and justifications included peer influence and the perceived safety of aphrodisiacs. Influential factors encompassed levels of knowledge, lifestyle, stress levels, erectile function, age, education, and the number of wives. Recommendations: Urgent policy interventions are warranted to regulate the acquisition and distribution of aphrodisiacs. Tailored health education initiatives should be implemented for married and prospective married men.

non-prescription drug usemale sexual healtherectile dysfunctionprevalence
مقالمفتوح (مستودع)20243استشهاد· Semantic Scholar

Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis

Arabian Journal of Chemistry · مجلد 17 (7) · 105837-105837

There are very limited analytical procedures to determine lemborexant (LMB) in dosage forms and biological materials. However, the literature does not provide any “high-performance thin-layer chromatographic (HPTLC)” assays to determine LMB. In an effort to analyze LMB in commercial pharmaceutical tablets more precisely, accurately, and sustainably than with the normal-phase-HPTLC (NP-HPTLC) approach, a sensitive and greener reverse-phase-HPTLC (RP-HPTLC) method was developed and validated. For NP-HPTLC, an acetone-petroleum ether (40:60 v/v) developing system was used. However, ethanol–water (85:15 v/v) was the developing system for RP-HPTLC. Four different techniques, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREENness (AGREE), were used to evaluate the greenness of both procedures. LMB measurement was linear in the 50–500 and 20–1000 ng/band ranges, respectively for NP and RP procedures. RP procedure was more robust (uncertainties = 0.90–0.95 %), accurate (recoveries = 98.24–101.57 %), precise (uncertainties = 0.87–1.00 %), linear (20–1000 ng/band), sensitive (LOD = 0.92 ng/band and LOQ = 2.76 ng/band), and greener over NP procedure. The results of greenness assessment using NEMI (all four circles green), AES (93), ChlorTox (0.88 g), and AGREE (0.89) demonstrated that the RP strategy was greener than NP strategy and all other reported HPLC methods. The fact that both techniques can assess LMB when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 89.24 % and 98.79 %, respectively, were the assay results for LMB in pharmaceutical tablets when utilizing the NP and RP procedures. Based on all validation and greenness metrics, it was found that RP procedure was better than the NP procedure. As a result, it is possible to assess LMB in pharmaceutical products using RP procedure.

lemborexantHPTLCgreen analytical chemistrymethod validation