جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

7 مُخرَج نتائج البحث عن «pharmaceutical quality control»

مقالوصول مفتوح202527استشهاد· Semantic Scholar

Application of machine learning assisted multi-variate UV spectrophotometric models augmented by kennard stone clustering algorithm for quantifying recently approved nasal spray combination of mometasone and olopatadine along with two genotoxic impurities: comprehensive sustainability assessment

BMC Chemistry · مجلد 19 (1) · 98-98

The recent approval of the nasal spray combination of mometasone (MOM) and olopatadine (OLO) presents a significant analytical challenge, as only a single reported method exists for its determination, deviating from eco-friendly practices. This study addresses this critical gap by pioneering the application of machine learning techniques to develop robust UV spectrophotometric approach for the simultaneous quantification of MOM and OLO, along with two genotoxic impurities: 4-dimethylamino pyridine (DAP) and methyl para-toluene sulfonate (MTS). By simultaneously determining these highly concerning genotoxic impurities and active pharmaceutical ingredients, this method underscores its paramount significance in upholding rigorous pharmaceutical quality standards and safeguarding patient safety. Applying the multilevel-multifactor experimental design, the calibration set was meticulously chosen at five different concentrations, yielding 25 calibration mixtures with central levels of 4, 46.5, 2.5, and 3 µg/mL for MOM, OLA, MTS, and DAP, respectively. The key innovation lies in the strategic implementation of the Kennard-Stone Clustering Algorithm to create a robust validation set of thirteen mixtures, resolving the limitations of reported chemometric methods' random data splitting. This approach ensures unbiased evaluation across the full concentration space, improving the method's reliability and sustainability. The robustness of this approach was rigorously tested using five distinct chemometric models: principal component regression, classical least squares, partial least squares, genetic algorithm-partial least squares, and multivariate curve resolution-alternating least squares, demonstrating its broad applicability across diverse modeling techniques. All models successfully determined all components with excellent recovery, low bias-corrected prediction, and adequate limits of detection. The Greenness Index Spider Charts and the Green Solvents Selection Tool were used to choose environmentally conscious solvents. A comprehensive sustainability assessment employed six state-of-the-art tools, including the national environmental method index, complementary green analytical procedure index, analytical greenness metric, blue applicability grade index, carbon footprint analysis, and the red-green-blue 12 metrics. Favorable results across all metrics affirmed the method's eco-friendliness, real-world applicability, and cost-effectiveness, supporting sustainable development goals in pharmaceutical quality control processes.

mometasoneolopatadinenasal spray formulationgenotoxic impurities
مقالمفتوح (مستودع)202416استشهاد· Semantic Scholar

Analysis of the greenness to determine risperidone in commercial products using a green stability-indicating HPTLC method

Arabian Journal of Chemistry · مجلد 17 (4) · 105693-105693

The purpose of this work was to develop and verify a green stability-indicating “high-performance thin-layer chromatographic (HPTLC)” technique to measure risperidone (RISP). The ternary mixture of ethanol, ethyl acetate, and ammonia (70:20:10 v/v/v) was the green mobile phase that was employed. At 281 nm, the detection of RISP was performed. The suggested method's greener profile was produced using the analytical eco-scale (AES), ChlorTox, and analytical GREENness (AGREE) methodologies. It was then contrasted with RISP analysis published HPTLC methods. The proposed methodology for measuring RISP in the 50–1400 ng/band range showed the linearity. Furthermore, the RISP measurement methodology was green, robust, precise (% RSD = 0.80–1.02), sensitive (LOD = 1.86 ng/band and LOQ = 5.60 ng/band), and accurate (% recoveries = 98.23–101.80). The AES, total ChlorTox, and AGREE scales for the suggested technique were found to be 83, 1.26 g, and 0.75, indicating an excellent greener profile. The current methodology's AES and total ChlorTox were significantly higher than those of previously published HPTLC RISP analysis methods. RISP was found to be highly stable under acid, base, and thermal stress conditions, while it was found to be most unstable under oxidative degradation conditions. Additionally, the stability-indicating aspect of the suggested technique was able to identify RISP in the presence of its degradation products. It was discovered that commercial tablet brands A and B had 98.12 and 99.62 % of RISP, respectively. The results of this investigation suggested that RISP in commercial formulations might be regularly analyzed utilizing the suggested green technology.

risperidonegreen analytical chemistrystability-indicating assayHPTLC
مقالوصول مفتوح20247استشهاد· Semantic Scholar

Simultaneous determination of lesinurad and febuxostat in commercial fixed-dose combinations using a greener normal-phase HPTLC method

Green Processing and Synthesis · مجلد 13 (1)

Abstract So far, no documented method for simultaneously analyzing lesinurad (LND) and febuxostat (FBX) has been reported for either traditional high-performance thin-layer chromatography (HPTLC) or a green HPTLC technique. In order to determine LND and FBX simultaneously in commercially available fixed-dose combo tablets, this study devised a normal-phase HPTLC method that is fast, sensitive, and green. The green eluents for the simultaneous analysis of LND and FBX were a mixture of ethyl acetate:ethanol:water at 70:20:10 (v/v/v) ratio. The new approach’s greenness was predicted utilizing four distinct greenness tools: the National Environmental Method Index, Analytical Eco-Scale, ChlorTox, and Analytical GREENness approaches, and the results revealed a significantly greener profile. The current method operated on a linear scale between 30 and 1,000 ng·band −1 . It was confirmed that the current approach is sensitive, accurate, precise, robust, and green. The LND and FBX contents of commercially available tablet products A and B were found to be within the range of 100 ± 2%, indicating that the existing methodology for simultaneously determining LND and FBX in pharmaceutical combination products is applicable. The results of the current methodology indicated that LND and FBX could be consistently measured in pharmaceutical combination products simultaneously using the current approach.

lesinuradfebuxostatfixed-dose combination tabletssimultaneous determination
مقالوصول مفتوح20239استشهاد· Semantic Scholar

Quantification of Pomalidomide Using Conventional and Eco-Friendly Stability-Indicating HPTLC Assays: A Contrast of Validation Parameters

ACS Omega · مجلد 8 (33) · 30655-30664

High-performance thin-layer chromatographic (HPTLC) assays for pomalidomide (PMD) measurement are lacking in the published database. Furthermore, eco-friendly stability-indicating analytical assays for PMD measurement are also lacking in the published database. In order to detect PMD in commercial products more accurately and sustainably than the conventional normal-phase HPTLC (NP-HPTLC) assay, an effort was made to design and verify a sensitive and eco-friendly reversed-phase HPTLC (RP-HPTLC) assay. The silica gel 60 NP-18F254S and 60 RP-18F254S plates were used as the stationary phases for NP-HPTLC and RP-HPTLC methods, respectively. The solvent system for NP-HPTLC was chloroform-methanol (90:10 v/v). However, the solvent system for RP-HPTLC was ethanol-water (75:25 v/v). The greenness scores for both assays were measured by AGREE approach. PMD measurement was performed for both assays at 372 nm. In the 50-600 and 20-1000 ng/band ranges, the NP-HPTLC and RP-HPTLC methods were linear for PMD measurement. The RP-HPTLC assay was superior to the NP-HPTLC method for measuring PMD in terms of sensitivity, accuracy, precision, and robustness. The ability of both methods to identify PMD in the presence of its degradation products suggests that both methods have stability-indicating features. When employing the NP-HPTLC and RP-HPTLC assays, respectively, the assay for PMD in commercial capsules was 88.68 and 98.83%. The AGREE scores for NP-HPTLC and RP-HPTLC assays were calculated to be 0.44 and 0.82, respectively, suggesting an outstanding greenness characteristic of the RP-HPTLC method than the NP-HPTLC method. The RP-HPTLC method was found to be superior to the NP-HPTLC method based on these findings. Therefore, the RP-HPTLC method could be successfully applied for the determination of PMD in pharmaceutical products.

pomalidomidereversed-phase HPTLCstability-indicating assaygreen analytical chemistry
مقالوصول مفتوح20239استشهاد· Semantic Scholar

Determination of Pterostilbene in Pharmaceutical Products Using a New HPLC Method and Its Application to Solubility and Stability Samples

Separations · مجلد 10 (3) · 178-178

The quantification of a natural bioactive compound, pterostilbene (PTT), in commercial capsule dosage form, solubility, and stability samples was carried out using a rapid and sensitive high-performance liquid chromatography (HPLC) approach. PTT was quantified on a Nucleodur (150 mm × 4.6 mm) RP C18 column with a particle size of 5 µm. Acetonitrile and water (90:10 v/v) made up the mobile phase, which was pumped at a flow speed of 1.0 mL/min. At a wavelength of 254 nm, PTT was detected. The developed HPLC approach was linear in 1–75 µg/g range, with a determination coefficient of 0.9995. The developed HPLC approach for PTT estimation was also rapid (Rt = 2.54 min), accurate (%recoveries = 98.10–101.93), precise (%CV = 0.59–1.25), and sensitive (LOD = 2.65 ng/g and LOQ = 7.95 ng/g). The applicability of developed HPLC approach was revealed by determining PTT in commercial capsule dosage form, solubility, and stability samples. The % assay of PTT in marketed capsules was determined to be 99.31%. The solubility of PTT in five different green solvents, including water, propylene glycol, ethanol, polyethylene glycol-400, and Carbitol was found to be 0.0180 mg/g, 1127 mg/g, 710.0 mg/g, 340.0 mg/g, and 571.0 mg/g, respectively. In addition, the precision and accuracy of stability samples were within the acceptable limit, hence PTT was found to be stable in solution. These results suggested that PTT in commercial products, solubility, and stability samples may be routinely determined using the established HPLC method.

pterostilbeneHPLC method developmentpharmaceutical quality controlcapsule dosage form
مقالوصول مفتوح20239استشهاد· Semantic Scholar

Development and Validation of a Stability-Indicating Greener HPTLC Method for the Estimation of Flufenamic Acid

Separations · مجلد 10 (1) · 39-39

The literature on ecofriendly/greener high-performance thin-layer chromatographic (HPTLC) methods for quantifying flufenamic acid (FFA) is scant. In order to develop and validate a stability-indicating greener HPTLC densitometry assay for FFA determination in marketed products, this research was conducted. The ecofriendly eluent system was composed of ethanol–water (70:30 v/v). FFA was measured at 290 nm of wavelength. The greenness scale of suggested analytical assay was derived using “Analytical GREENness (AGREE)” methodology. The suggested stability-indicating HPTLC assay was linear for FFA determination in 25–1400 ng/band range with a determination coefficient of 0.9974. The suggested analytical assay for FFA analysis was simple, rapid, accurate, precise, robust, selective, stability-indicating, and greener. The AGREE scale for the developed stability-indicating HPTLC assay was derived to be 0.77 utilizing AGREE methodology, indicating an outstanding greenness characteristic of the suggested densitometry technique. The ecofriendly HPTLC technique was able to detect FFA degradation product under forced degradation studies, indicating its stability-indication characteristics and selectivity. The amount of FFA in marketed tablets brand A and B was determined to be 101.28 and 99.17%, respectively, indicating the suitability of the suggested analytical technique in the assay of FFA in marketed products. These results indicated that FFA in marketed products may be routinely measured using the stability-indicating greener HPTLC technique.

flufenamic acidstability-indicating assaygreen analytical chemistrydensitometry
مقالوصول مفتوح20222استشهاد· Semantic Scholar

A Greener Stability-Indicating High-Performance Thin-Layer Chromatography Approach for the Estimation of Topiramate

Materials · مجلد 15 (5) · 1731-1731

Despite various reported analytical methods for topiramate (TPM) analysis, greener analytical approaches are scarce in literature. As a consequence, the objective of the current research is to design a normal-phase stability-indicating high-performance thin-layer chromatography (SI-HPTLC) methodology for TPM analysis in marketed tablet dosage forms that is rapid, sensitive, and greener. TPM was derivatized densitometrically and analyzed at 423 nm in visible mode with anisaldehyde-sulfuric acid as the derivatizing agent. The greener SI-HPTLC technique was linear in the 30–1200 ng band−1 range. In addition, the suggested SI-HPTLC methodology for TPM analysis was simple, rapid, cheaper, precise, robust, sensitive, and environmentally friendly. The greener SI-HPTLC method was able to detect TPM along with its degradation products under acid, base, and oxidative degradation conditions. However, no TPM degradation was recorded under thermal and photolytic stress conditions. TPM contents in commercial tablet dosage forms were recorded as 99.14%. Using 12 different principles of green analytical chemistry, the overall analytical GREEnness (AGREE) score for the greener SI-HPTLC method was calculated to be 0.76, confirming the proposed normal-phase SI-HPTLC method’s good greener nature. Overall, these results demonstrated that the suggested SI-HPTLC technique for TPM measurement in pharmaceutical products was reliable and selective.

topiramategreen analytical chemistrydegradation productstablets