جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

2 مُخرَج نتائج البحث عن «pharmaceutical quality control»

مقالوصول مفتوح202527استشهاد· Semantic Scholar

Application of machine learning assisted multi-variate UV spectrophotometric models augmented by kennard stone clustering algorithm for quantifying recently approved nasal spray combination of mometasone and olopatadine along with two genotoxic impurities: comprehensive sustainability assessment

BMC Chemistry · مجلد 19 (1) · 98-98

The recent approval of the nasal spray combination of mometasone (MOM) and olopatadine (OLO) presents a significant analytical challenge, as only a single reported method exists for its determination, deviating from eco-friendly practices. This study addresses this critical gap by pioneering the application of machine learning techniques to develop robust UV spectrophotometric approach for the simultaneous quantification of MOM and OLO, along with two genotoxic impurities: 4-dimethylamino pyridine (DAP) and methyl para-toluene sulfonate (MTS). By simultaneously determining these highly concerning genotoxic impurities and active pharmaceutical ingredients, this method underscores its paramount significance in upholding rigorous pharmaceutical quality standards and safeguarding patient safety. Applying the multilevel-multifactor experimental design, the calibration set was meticulously chosen at five different concentrations, yielding 25 calibration mixtures with central levels of 4, 46.5, 2.5, and 3 µg/mL for MOM, OLA, MTS, and DAP, respectively. The key innovation lies in the strategic implementation of the Kennard-Stone Clustering Algorithm to create a robust validation set of thirteen mixtures, resolving the limitations of reported chemometric methods' random data splitting. This approach ensures unbiased evaluation across the full concentration space, improving the method's reliability and sustainability. The robustness of this approach was rigorously tested using five distinct chemometric models: principal component regression, classical least squares, partial least squares, genetic algorithm-partial least squares, and multivariate curve resolution-alternating least squares, demonstrating its broad applicability across diverse modeling techniques. All models successfully determined all components with excellent recovery, low bias-corrected prediction, and adequate limits of detection. The Greenness Index Spider Charts and the Green Solvents Selection Tool were used to choose environmentally conscious solvents. A comprehensive sustainability assessment employed six state-of-the-art tools, including the national environmental method index, complementary green analytical procedure index, analytical greenness metric, blue applicability grade index, carbon footprint analysis, and the red-green-blue 12 metrics. Favorable results across all metrics affirmed the method's eco-friendliness, real-world applicability, and cost-effectiveness, supporting sustainable development goals in pharmaceutical quality control processes.

mometasoneolopatadinenasal spray formulationgenotoxic impurities
مقالوصول مفتوح20239استشهاد· Semantic Scholar

Quantification of Pomalidomide Using Conventional and Eco-Friendly Stability-Indicating HPTLC Assays: A Contrast of Validation Parameters

ACS Omega · مجلد 8 (33) · 30655-30664

High-performance thin-layer chromatographic (HPTLC) assays for pomalidomide (PMD) measurement are lacking in the published database. Furthermore, eco-friendly stability-indicating analytical assays for PMD measurement are also lacking in the published database. In order to detect PMD in commercial products more accurately and sustainably than the conventional normal-phase HPTLC (NP-HPTLC) assay, an effort was made to design and verify a sensitive and eco-friendly reversed-phase HPTLC (RP-HPTLC) assay. The silica gel 60 NP-18F254S and 60 RP-18F254S plates were used as the stationary phases for NP-HPTLC and RP-HPTLC methods, respectively. The solvent system for NP-HPTLC was chloroform-methanol (90:10 v/v). However, the solvent system for RP-HPTLC was ethanol-water (75:25 v/v). The greenness scores for both assays were measured by AGREE approach. PMD measurement was performed for both assays at 372 nm. In the 50-600 and 20-1000 ng/band ranges, the NP-HPTLC and RP-HPTLC methods were linear for PMD measurement. The RP-HPTLC assay was superior to the NP-HPTLC method for measuring PMD in terms of sensitivity, accuracy, precision, and robustness. The ability of both methods to identify PMD in the presence of its degradation products suggests that both methods have stability-indicating features. When employing the NP-HPTLC and RP-HPTLC assays, respectively, the assay for PMD in commercial capsules was 88.68 and 98.83%. The AGREE scores for NP-HPTLC and RP-HPTLC assays were calculated to be 0.44 and 0.82, respectively, suggesting an outstanding greenness characteristic of the RP-HPTLC method than the NP-HPTLC method. The RP-HPTLC method was found to be superior to the NP-HPTLC method based on these findings. Therefore, the RP-HPTLC method could be successfully applied for the determination of PMD in pharmaceutical products.

pomalidomidereversed-phase HPTLCstability-indicating assaygreen analytical chemistry