Arabian Journal of Chemistry · مجلد 17 (2) · 105571-105571
The greener “high-performance thin-layer chromatography (HPTLC)” methods for apremilast (APM) analysis in pharmaceutical products and biological fluids are not currently available in the literature. Accordingly, this study involves the development and validation of a rapid, simple, economical, and greener reversed-phase HPTLC methodology for the estimation of APM in prepared nanoparticles (NPs), nanoemulsion, and marketed tablets. The estimation of APM was conducted using “RP-18 silica gel 60 F254S HPTLC plates” as the stationary phase. The combination of ethanol/water (65:35, v/v) was used as the greener mobile phase for APM analysis. The greenness of the method was predicted using three different approaches, namely Analytical Eco-Score (AES), ChlorTox, and the Analytical GREENness (AGREE) approaches. The λmax = 238 nm was used for the APM detection. By contrasting its single band at Rf = 0.61 ± 0.01 with those of pure APM, the HPTLC peaks for APM in an prepared NP formulation, nanoemulsion, and marketed tablets were identified. In the concentration range of 100-700 ng/band, the proposed analytical methodology was linear. The values of AES, ChlorTox, and AGREE were determined to be 95, 0.66 g, and 0.89, respectively, demonstrated an outstanding greener profile for the existing method. The amount of APM in the tablet, NP formulation, nanoemulsion was found to be 98.40, 101.60, and 99.37%, respectively. According to the findings of validation tests and pharmaceutical analysis, the suggested analytical technique could be successfully applied for the routine examination of APM in marketed tablets and laboratory generated nanoformulations.
The literature on ecofriendly/greener high-performance thin-layer chromatographic (HPTLC) methods for quantifying flufenamic acid (FFA) is scant. In order to develop and validate a stability-indicating greener HPTLC densitometry assay for FFA determination in marketed products, this research was conducted. The ecofriendly eluent system was composed of ethanol–water (70:30 v/v). FFA was measured at 290 nm of wavelength. The greenness scale of suggested analytical assay was derived using “Analytical GREENness (AGREE)” methodology. The suggested stability-indicating HPTLC assay was linear for FFA determination in 25–1400 ng/band range with a determination coefficient of 0.9974. The suggested analytical assay for FFA analysis was simple, rapid, accurate, precise, robust, selective, stability-indicating, and greener. The AGREE scale for the developed stability-indicating HPTLC assay was derived to be 0.77 utilizing AGREE methodology, indicating an outstanding greenness characteristic of the suggested densitometry technique. The ecofriendly HPTLC technique was able to detect FFA degradation product under forced degradation studies, indicating its stability-indication characteristics and selectivity. The amount of FFA in marketed tablets brand A and B was determined to be 101.28 and 99.17%, respectively, indicating the suitability of the suggested analytical technique in the assay of FFA in marketed products. These results indicated that FFA in marketed products may be routinely measured using the stability-indicating greener HPTLC technique.
High Resolution Image Download MS PowerPoint Slide Suvorexant (SUV) is a new sedative/hypnotic medicine that is recommended to treat insomnia. It is an important medicine from a forensic point of view due to its sedative/hypnotic and depressant effects. To the best of our knowledge, high-performance thin-layer chromatography (HPTLC) bioanalytical methods have not been published to measure SUV in human urine and pharmaceutical samples. Accordingly, this study was designed and validated a sensitive and rapid bioanalytical HPTLC method to determine SUV in human urine samples for the very first time. The densitometric measurement of SUV and the internal standard (IS; sildenafil) was performed on glass-coated silica gel normal-phase-60F254S TLC plates using a mixture of chloroform and methanol (97.5:2.5 v/v) as the eluent system. Both the SUV and IS were detected at a wavelength of 254 nm. Both analytes were extracted using the protein precipitation technique utilizing methanol as the solvent. For the IS and SUV, the R f values were 0.09 and 0.45, respectively. The proposed bioanalytical method for SUV was linear in the 50–1600 ng/band range. The current bioanalytical technique was linear, precise (% RSD = 3.28–4.20), accurate (% recovery = 97.58–103.80), robust (% recovery = 95.31–102.34 and % RSD = 2.81–3.15), rapid, and sensitive (LOD = 3.73 ng/band and LOQ = 11.20 ng/band). These findings suggested that the current bioanalytical method can be regularly used to determine SUV in wide varieties of urine samples.