جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

19 مُخرَج نتائج البحث عن «method validation»

مقالوصول مفتوح20229استشهاد· Semantic Scholar

A Simple, Cost-Effective, and Green HPTLC Method for the Estimation of Ascorbic Acid in Solvent and Ultrasound-Assisted Extracts of Phyllanthus emblica, Capsicum annuum, and Psidium guajava

Agronomy · مجلد 12 (5) · 1016-1016

Greener analytical methodologies for the estimation of ascorbic acid (AA) are poorly reported in the literature. Furthermore, the green indexes of the literature’s analytical assays of AA estimation have not been assessed. As a consequence, the aim of this research is to invent and validate a simple, cost-effective, and green reverse-phase “high-performance thin-layer chromatography (HPTLC)” method for the estimating AA in the solvent extracts (SE) and ultrasound-assisted extracts (UAE) of Phyllanthus emblica, Psidium guajava, and Capsicum annuum. The greener mobile phase for AA estimation was a binary mixture of water and ethanol (70:30, v/v). At a wavelength of 265 nm, the detection of AA was carried out. The greener HPTLC technique was linear in the 25–1200 ng/band range. In addition, the method was simple, cost-effective, accurate, precise, robust, sensitive, and green. The amount of AA was highest in the SE and UAE of P. emblica compared to the SE and UAE of P. guajava and C. annuum. The amount of AA in the SE of P. emblica, P. guajava, and C. annuum was found to be 491.16, 168.91, and 144.30 mg/100 g, respectively. However, the amount of AA in the UAE of P. emblica, P. guajava, and C. annuum was found to be 673.02, 218.71, and 199.30 mg/100 g, respectively. Using the “analytical GREEnness (AGREE)” methodology, the greenness index for the developed method was calculated to be 0.88, showing that the developed method has an excellent green profile. When it came to extracting AA, the UAE method outperformed the SE method. These findings suggested that the developed method might be used to estimate the AA in a variety of vegetable crops, plant-based extracts, and commercial formulations. Furthermore, because of the use of greener solvent systems against the commonly utilized hazardous solvent systems for AA determination, this technique is also safe and sustainable.

vitamin Cultrasound-assisted extractionsolvent extractionPhyllanthus emblica
مقالوصول مفتوح20227استشهاد· Semantic Scholar

Determination of Gefitinib Using Routine and Greener Stability-Indicating HPTLC Methods: A Comparative Evaluation of Validation Parameters

Processes · مجلد 10 (4) · 762-762

“High-performance thin-layer chromatography (HPTLC)” methods for gefitinib (GFT) estimation are scarce in the literature. In addition, greener analytical techniques for GFT estimation are also lacking in the literature. Accordingly, an attempt was undertaken to invent and validate a sensitive and greener normal-phase HPTLC method for GFT analysis in commercial tablets in comparison to the routine normal-phase HPTLC method. The greenness index for both methods was assessed using “Analytical GREENness (AGREE)” methodology. GFT detection was carried out using both methods at 332.0 nm. In the 30–700 ng/band and 20–1400 ng/band ranges, the routine and greener HPTLC assays were linear for GFT estimation. The greener HPTLC method was highly sensitive, more accurate, more precise, and more robust than the routine HPTLC assay for GFT estimation. Both methods were able to detect GFT in the presence of its degradation products, suggesting the stability-indicating property of both methods. The assay of GFT in commercial tablets was 92.45% and 99.74% using the routine and greener HPTLC assays, respectively. The AGREE index for routine and greener analytical assays was predicted to be 0.44 and 0.77, respectively, indicating the excellent greenness index of the greener HPTLC assay over the routine HPTLC assay. The greener HPTLC assay is considered superior to the routine HPTLC assay based on these results.

gefitinibHPTLC method developmentgreen analytical chemistrystability-indicating assay
مقالوصول مفتوح20221استشهاد· Semantic Scholar

UPLC-MS/MS-Based Analysis of Trastuzumab in Plasma Samples: Application in Breast Cancer Patients Sample Monitoring

Processes · مجلد 10 (3) · 509-509

Trastuzumab is a target-based recombinant humanized IgG1 monoclonal antibody (mAbs), extensively employed for treatment of metastatic breast cancer with human epidermal growth receptor 2 (HER2) overexpression. Studies around the world have reported that mAbs have substantial inter-patient unpredictable absorption, distribution, metabolism, and excretion (ADME-pharmacokinetics) because of multiple elements manipulating the concentration of mAbs in plasma. Herein, we have established a bioanalytical technique using UPLC-MS/MS with an easy sample workup method and in-solution digestion protocol to assay the trastuzumab plasma samples from breast cancer patients in clinical studies. Surrogated proteolytic peptides were used for accurate quantification of trastuzumab (CanMab) with a trastuzumab signature peptide with [13C6, 15N4]-arginine and [13C6, 15N2]-lysine stable isotope-labeled (SIL) peptide. Experiments to validate the method were accurately carried out according to the guidelines mentioned in the bioanalytical method validation protocol. The evaluation established excellent linearity over a wide range of 5–500 µg/mL. The experimental procedure was efficaciously performed in a pilot study of five breast cancer patients and residual concentrations of drugs from responding and non-responding subjects were compared. The receiver operating characteristic (ROC) examination displayed that 52.25 µg/mL was the Cmin threshold predictive response with a satisfactory sensitivity of 88.58% and specificity of 79.25%.

trastuzumabplasma drug quantificationbreast cancerHER2-positive metastatic breast cancer
مقالوصول مفتوح20212استشهاد· Semantic Scholar

Rapid, Highly-Sensitive and Ecologically Greener Reversed-Phase/Normal-Phase HPTLC Technique with Univariate Calibration for the Determination of Trans-Resveratrol

Separations · مجلد 8 (10) · 184-184

The rapid, highly-sensitive and ecologically greener reversed-phase (RP)/normal-phase (NP) high-performance thin-layer chromatography (HPTLC) densitometric technique has been developed and validated for the determination of trans-resveratrol (TRV). The reversed-phase HPTLC-based analysis of TRV was performed using ethanol–water (65:35, v v−1) combination as the greener mobile phase, while, the normal-phase HPTLC-based estimation of TRV was performed using chloroform–methanol (85:15, v v−1) combination as the routine mobile phase. The TRV detection was carried out at 302 nm for RP/NP densitometric assay. The linearity was recorded as 10–1200 and 30–400 ng band−1 for RP and NP HPTLC techniques, respectively. The RP densitometric assay was observed as highly-sensitive, accurate, precise and robust for TRV detection in comparison with the NP densitometric assay. The contents of TRV in commercial formulation were recorded as 101.21% utilizing the RP densitometric assay, while, the contents of TRV in commercial formulation were found to be 91.64% utilizing the NP densitometric assay. The greener profile of RP/NP technique was obtained using the analytical GREEnness (AGREE) approach. The AGREE scales for RP and NP densitometric assays were estimated 0.75 and 0.48, respectively. The recorded AGREE scale for the RP densitometric assay indicated that this technique was highly green/the ecologically greener compared to the NP densitometric assay. After successful optimization of analytical conditions, validation parameters, AGREE scale and chromatography performance, the RP densitometric assay with univariate calibration was found to be better than the NP densitometric assay for the analysis of TRV.

trans-resveratrolreversed-phase HPTLCgreen analytical chemistryunivariate calibration