International Journal of Analytical Chemistry · مجلد 2026 (1) · 4376722-4376722
Dasatinib, a therapy for chronic myeloid leukemia, suffers from poor bioavailability. Self‐microemulsifying drug delivery systems (SMEDDSs) are used to improve its dissolution. This study aimed to develop and validate a novel reverse‐phase high‐performance liquid chromatography (RP‐HPLC) method for quantifying dasatinib in SMEDDS formulations. The RP‐HPLC method utilized a mobile phase of methanol and 0.1% trifluoroacetic acid (55:45, v/v) and identified a peak wavelength for dasatinib at 324 nm. SMEDDS formulations comprised Capryol 90, Transcutol HP, and Tween 40. The method was validated according to ICH guidelines, demonstrating excellent linearity ( R 2 = 0.9993), accuracy (recovery between 98% and 101%), and precision (relative standard deviation of 0.73%). It also showed stability and reliability with limits of detection and quantification of 0.17 and 0.50 µg/mL, respectively. This RP‐HPLC method meets all validation criteria and provides a robust, cost‐effective tool for analyzing dasatinib in SMEDDS formulations.
dasatinibself-microemulsifying drug delivery systemRP-HPLC method developmentmethod validation
The literature does not provide any "high-performance thin-layer chromatographic (HPTLC)" techniques for the determination of a novel antidiabetic medicine, ertugliflozin (ERZ). Additionally, there are not many environmentally friendly analytical methods for ERZ measurement in the literature. A rapid, sensitive, and eco-friendly reversed-phase-HPTLC (RP-HPTLC) method was designed and validated in an attempt to analyze ERZ in marketed pharmaceutical tablets more precisely, accurately, and sustainably over the traditional normal-phase HPTLC (NP-HPTLC) method. The stationary phases used in the NP- and RP-HPTLC procedures were silica gel 60 NP-18F254S and 60 RP-18F254S plates, respectively. For NP-HPTLC, a chloroform/methanol (85:15 v/v) mobile phase was used. However, ethanol-water (80:20 v/v) was the preferred method for RP-HPTLC. Four distinct methodologies, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREEnness (AGREE) approaches, were used to evaluate the greenness of both procedures. For both approaches, ERZ detection was carried out at 199 nm. Using the NP- and RP-HPTLC techniques, the ERZ measurement was linear in the 50-600 and 25-1200 ng/band ranges. The RP-HPTLC method was found to be more robust, accurate, precise, linear, sensitive, and eco-friendly compared to the NP-HPTLC approach. The results of four greenness tools demonstrated that the RP strategy was greener than the NP strategy and all other reported HPLC techniques. The fact that both techniques can assess ERZ when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 87.41 and 99.28%, respectively, were the assay results for ERZ in commercial tablets when utilizing the NP and RP procedures. Based on several validation and greenness metrics, it was determined that the RP-HPTLC approach was better than the NP-HPTLC method. As a result, it is possible to determine ERZ in pharmaceutical products using the RP-HPTLC approach.
Arabian Journal of Chemistry · مجلد 17 (7) · 105837-105837
There are very limited analytical procedures to determine lemborexant (LMB) in dosage forms and biological materials. However, the literature does not provide any “high-performance thin-layer chromatographic (HPTLC)” assays to determine LMB. In an effort to analyze LMB in commercial pharmaceutical tablets more precisely, accurately, and sustainably than with the normal-phase-HPTLC (NP-HPTLC) approach, a sensitive and greener reverse-phase-HPTLC (RP-HPTLC) method was developed and validated. For NP-HPTLC, an acetone-petroleum ether (40:60 v/v) developing system was used. However, ethanol–water (85:15 v/v) was the developing system for RP-HPTLC. Four different techniques, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREENness (AGREE), were used to evaluate the greenness of both procedures. LMB measurement was linear in the 50–500 and 20–1000 ng/band ranges, respectively for NP and RP procedures. RP procedure was more robust (uncertainties = 0.90–0.95 %), accurate (recoveries = 98.24–101.57 %), precise (uncertainties = 0.87–1.00 %), linear (20–1000 ng/band), sensitive (LOD = 0.92 ng/band and LOQ = 2.76 ng/band), and greener over NP procedure. The results of greenness assessment using NEMI (all four circles green), AES (93), ChlorTox (0.88 g), and AGREE (0.89) demonstrated that the RP strategy was greener than NP strategy and all other reported HPLC methods. The fact that both techniques can assess LMB when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 89.24 % and 98.79 %, respectively, were the assay results for LMB in pharmaceutical tablets when utilizing the NP and RP procedures. Based on all validation and greenness metrics, it was found that RP procedure was better than the NP procedure. As a result, it is possible to assess LMB in pharmaceutical products using RP procedure.
Arabian Journal of Chemistry · مجلد 17 (2) · 105571-105571
The greener “high-performance thin-layer chromatography (HPTLC)” methods for apremilast (APM) analysis in pharmaceutical products and biological fluids are not currently available in the literature. Accordingly, this study involves the development and validation of a rapid, simple, economical, and greener reversed-phase HPTLC methodology for the estimation of APM in prepared nanoparticles (NPs), nanoemulsion, and marketed tablets. The estimation of APM was conducted using “RP-18 silica gel 60 F254S HPTLC plates” as the stationary phase. The combination of ethanol/water (65:35, v/v) was used as the greener mobile phase for APM analysis. The greenness of the method was predicted using three different approaches, namely Analytical Eco-Score (AES), ChlorTox, and the Analytical GREENness (AGREE) approaches. The λmax = 238 nm was used for the APM detection. By contrasting its single band at Rf = 0.61 ± 0.01 with those of pure APM, the HPTLC peaks for APM in an prepared NP formulation, nanoemulsion, and marketed tablets were identified. In the concentration range of 100-700 ng/band, the proposed analytical methodology was linear. The values of AES, ChlorTox, and AGREE were determined to be 95, 0.66 g, and 0.89, respectively, demonstrated an outstanding greener profile for the existing method. The amount of APM in the tablet, NP formulation, nanoemulsion was found to be 98.40, 101.60, and 99.37%, respectively. According to the findings of validation tests and pharmaceutical analysis, the suggested analytical technique could be successfully applied for the routine examination of APM in marketed tablets and laboratory generated nanoformulations.
The eco-friendly high-performance thin-layer chromatographic (HPTLC) approaches for measuring cinnarizine (CIN) are scant in reported databases. As a result, the current work has developed and validated an eco-friendly HPTLC technique for assessing CIN in commercial formulations. The proposed approach was based the use of ethyl alcohol-water (90:10 v/v) as the eco-friendly mobile phase. A wavelength of 197 nm was used to detect CIN. The greenness score of the current approach was measured using the Analytical GREENness (AGREE) approach. The current approach was linear for CIN measurement in 50–800 ng band−1 range. The current approach for CIN measurement was validated successfully using ICH guidelines and was found to be linear, accurate (% recovery = 99.07–101.29%), precise (% CV = 0.80–0.95%), robust, sensitive (LOD = 16.81 ng band−1 and LOQ = 50.43 ng band−1), specific, selective, stability-indicating, and eco-friendly. The AGREE score for the current approach was calculated to be 0.80, showing an excellent greenness characteristic of the present approach. Under forced degradation conditions, the current approach was successful in separating the CIN degradation product, demonstrating the stability-indicating qualities/selectivity of the present approach. The % assay of CIN in commercial tablet brands A and B was found to be 98.64 and 101.22%, respectively, suggesting the reliability of the present approach in the pharmaceutical analysis of CIN in commercial dosage forms. The obtained findings indicated that CIN in commercial formulations could be routinely determined using the current approach.
High Resolution Image Download MS PowerPoint Slide Suvorexant (SUV) is a new sedative/hypnotic medicine that is recommended to treat insomnia. It is an important medicine from a forensic point of view due to its sedative/hypnotic and depressant effects. To the best of our knowledge, high-performance thin-layer chromatography (HPTLC) bioanalytical methods have not been published to measure SUV in human urine and pharmaceutical samples. Accordingly, this study was designed and validated a sensitive and rapid bioanalytical HPTLC method to determine SUV in human urine samples for the very first time. The densitometric measurement of SUV and the internal standard (IS; sildenafil) was performed on glass-coated silica gel normal-phase-60F254S TLC plates using a mixture of chloroform and methanol (97.5:2.5 v/v) as the eluent system. Both the SUV and IS were detected at a wavelength of 254 nm. Both analytes were extracted using the protein precipitation technique utilizing methanol as the solvent. For the IS and SUV, the R f values were 0.09 and 0.45, respectively. The proposed bioanalytical method for SUV was linear in the 50–1600 ng/band range. The current bioanalytical technique was linear, precise (% RSD = 3.28–4.20), accurate (% recovery = 97.58–103.80), robust (% recovery = 95.31–102.34 and % RSD = 2.81–3.15), rapid, and sensitive (LOD = 3.73 ng/band and LOQ = 11.20 ng/band). These findings suggested that the current bioanalytical method can be regularly used to determine SUV in wide varieties of urine samples.
Four simple, specific, easy, precise and accurate spectrophotometric methods were developed for the first time to examine ciprofloxacin and metronidazole in combination, without having been separated beforehand by the developed methods. Ciprofloxacin and metronidazole were determined by utilizing advanced absorbance subtraction (AAS), spectrum subtraction, bivariate and ratio difference methods. Precision, repeatability, robustness, and accuracy were all determined to be within acceptable levels after each of these procedures underwent validation in accordance with ICH recommendations. Each method's benefits and drawbacks are illustrated, and the proposed and reported methodologies were statistically compared.
ciprofloxacinmetronidazolecombination drug formulationspectrum subtraction
A well-known direct-acting antiviral (DAA) drug called daclatasvir may be used to treat chronic hepatitis C virus (HCV) infection. Herein, we reported a selective, precise, and a cost-effective analytical method for the measurement of an active pharmaceutical ingredient (API) of daclatasvir dihydrochloride in drug substances as well as drug products via the reversed-phase RP-HPLC technique. To obtain greater separation, the majority of the chromatographic conditions were improved. Best separation findings were achieved under chromatographic conditions with an HPLC column of USP L1 (150 × 4.6 mm, 5 μm) by utilizing a combination of acetonitrile and buffer solution of KH2PO4 (30 : 70, v/v) as a mobile phase at a stream rate of 1 mL.min−1 with a finding at 300 nm and a column temperature of 40°C. Linearity was examined in the range of 90–210 ppm (R2 = 0.999) for daclatasvir dihydrochloride. The new technique has been verified using industry-recognized criteria, including applicability, system precision, accuracy, robustness, specificity, range, linearity, quantification limit, reagent stability, and detection limit. All the measured metrics were determined to be within acceptable limits using the criteria of the Worldwide Council for Harmonisation (ICH). In pharmaceutical labs, daclatasvir dihydrochloride may be analyzed qualitatively and quantitatively using the well-established RP-HPLC technique. Our study also highlights the need to evaluate the greenness of the method developed using a recognized tool ,i.e., Analytical Greenness Metrics (AGREE).
RP-HPLC method validationanalytical method developmentdirect-acting antiviralshepatitis C
An accurate, precise and sensitive reverse-phase high-performance liquid chromatography (RP-HPLC) bioanalytical approach was developed for the simultaneous estimation of cinnarizine (CIN) and domperidone (DOM) in rat plasma using irbesartan (IRB) as an internal standard (IS). The proposed RP-HPLC approach was validated as per the latest ICH M10 guidelines. The analytes (CIN and DOM) and IS were extracted from plasma samples using the protein precipitation strategy. Chromatographic separation is accomplished by a C18 SunfireTM (5 µm, 250 mm × 4.6 mm) analytical column, using an isocratic mobile phase consisting of acetonitrile-methanol in 30:70 proportions at a flow rate of 1 mL/min. The detection of all three constituents was recorded at a wavelength of 270 nm with a UV detector. DOM, CIN and IS were eluted at 3.2, 4.5 and 6.1 min, respectively, utilizing a total run time of 10 min. The lower limit of quantification (LLOQ) was 5 ng/mL for CIN and DOM in rat plasma. The proposed RP-HPLC approach was linear in the 5–200 ng/mL range for CIN and DOM. The recovery of the method was greater than 95%, and the relative uncertainty was less than 2%, indicating that the proposed bioanalytical approach was accurate and precise. The limit of detection was established as 1.1 ng/mL for CIN and 1.7 ng/mL for DOM. The created approach was found to be robust and passed all validation criteria; thus, the proposed RP-HPLC approach can be employed successfully for the simultaneous assessment of CIN and DOM in rat plasma.
Thymoquinone (THY) is a bioactive compound present in the seed powder of Nigella sativa (NS). This research aims to precisely and accurately estimate THY using high-performance liquid chromatography (HPLC) with a Quality by Design (QbD) application. Box-Behnken design (BBD) was employed to optimize the chromatographic conditions for HPLC method development, taking mobile phase flow rate, pH of the buffer, and λmax as independent variables and retention time and tailing factor as the measured responses. The mobile phase composition was methanol: acetonitrile: buffer (2.2 mM ammonium formate) at the ratio of 35:50:15 v/v/v on a Symmetry® C18 (5 μm, 3.9 × 150 mm) column. In isocratic mode, it had a flow rate 0.9 mL min−1 and eluted analyte was detected at 249 nm. Validation parameters followed the International Council for Harmonization (ICH) guidelines for the new HPLC method. The method was linear over the range 6.25–100 µg mL−1 with a coefficient of determination (r2) of 0.9957. The limit of detection (LOD) and limit of quantification (LOQ) were 2.05 and 6.25 µg mL−1, respectively. The %RSD of system suitability for retention time was 1.42% and for the tailing factor it was 0.695%. In addition, the developed method was precise, accurate, and robust according to ICH criteria. The developed HPLC method is simple, accurate, quick, and robust, and it could be used for the routine analysis of THY in different kinds of formulations.
thymoquinoneNigella sativaseed powderRP-HPLC method development
There has been no assessment of the greenness of the described analytical techniques for the simultaneous determination (SMD) of caffeine and paracetamol. As a result, in comparison to the greener normal-phase high-performance thin-layer chromatography (HPTLC) technique, this research was conducted to develop a rapid, sensitive, and greener reversed-phase HPTLC approach for the SMD of caffeine and paracetamol in commercial formulations. The greenness of both techniques was calculated using the AGREE method. For the SMD of caffeine and paracetamol, the greener normal-phase and reversed-phase HPTLC methods were linear in the 50-500 ng/band and 25-800 ng/band ranges, respectively. For the SMD of caffeine and paracetamol, the greener reversed-phase HPTLC approach was more sensitive, accurate, precise, and robust than the greener normal-phase HPTLC technique. For the SMD of caffeine paracetamol in commercial PANEXT and SAFEXT tablets, the greener reversed-phase HPTLC technique was superior to the greener normal-phase HPTLC approach. The AGREE scores for the greener normal-phase and reversed-phase HPTLC approaches were estimated as 0.81 and 0.83, respectively, indicated excellent greenness profiles for both analytical approaches. The greener reversed-phase HPTLC approach is judged superior to the greener normal-phase HPTLC approach based on numerous validation parameters and pharmaceutical assays.
Common methodologies such as liquid-liquid extraction and solid-phase extraction are applied for the extraction of opioids from biological specimens i.e., blood and urine. Techniques including LC-MS/LC-MSMS, GC-MS, etc. are used for qualitative or quantitative determination of opioids. The goal of the present work is to design a green, economic, rugged, and simple extraction technique for famous opioids in human blood and urine and their simultaneous quantification by GC-MS equipped with an inert plus electron impact (EI) ionization source at SIM mode to produce reproducible and efficient results. Morphine, codeine, 6-acetylmorphine, nalbuphine, tramadol and dextromethorphan were selected as target opioids. Anhydrous Epsom salt was applied for dSPE of opioids from blood and urine into acetonitrile extraction solvent with the addition of sodium phosphate buffer (pH 6) and n-hexane was added to remove non-polar interfering species from samples. BSTFA was used as a derivatizing agent for GC-MS. Following method validation, the LOD/LLOQ and ULOQ were determined for morphine, codeine, nal-buphine, tramadol, and dextromethorphan at 10 ng/mL and 1500 ng/mL, respectively, while the LOD/LLOQ and ULOQ were determined for 6-acetylmorphine at 5 ng/mL and 150 ng/mL, respectively. This method was applied to real blood and urine samples of opioid abusers and the results were found to be reproducible with true quantification.
Greener analytical methodologies for the estimation of ascorbic acid (AA) are poorly reported in the literature. Furthermore, the green indexes of the literature’s analytical assays of AA estimation have not been assessed. As a consequence, the aim of this research is to invent and validate a simple, cost-effective, and green reverse-phase “high-performance thin-layer chromatography (HPTLC)” method for the estimating AA in the solvent extracts (SE) and ultrasound-assisted extracts (UAE) of Phyllanthus emblica, Psidium guajava, and Capsicum annuum. The greener mobile phase for AA estimation was a binary mixture of water and ethanol (70:30, v/v). At a wavelength of 265 nm, the detection of AA was carried out. The greener HPTLC technique was linear in the 25–1200 ng/band range. In addition, the method was simple, cost-effective, accurate, precise, robust, sensitive, and green. The amount of AA was highest in the SE and UAE of P. emblica compared to the SE and UAE of P. guajava and C. annuum. The amount of AA in the SE of P. emblica, P. guajava, and C. annuum was found to be 491.16, 168.91, and 144.30 mg/100 g, respectively. However, the amount of AA in the UAE of P. emblica, P. guajava, and C. annuum was found to be 673.02, 218.71, and 199.30 mg/100 g, respectively. Using the “analytical GREEnness (AGREE)” methodology, the greenness index for the developed method was calculated to be 0.88, showing that the developed method has an excellent green profile. When it came to extracting AA, the UAE method outperformed the SE method. These findings suggested that the developed method might be used to estimate the AA in a variety of vegetable crops, plant-based extracts, and commercial formulations. Furthermore, because of the use of greener solvent systems against the commonly utilized hazardous solvent systems for AA determination, this technique is also safe and sustainable.
“High-performance thin-layer chromatography (HPTLC)” methods for gefitinib (GFT) estimation are scarce in the literature. In addition, greener analytical techniques for GFT estimation are also lacking in the literature. Accordingly, an attempt was undertaken to invent and validate a sensitive and greener normal-phase HPTLC method for GFT analysis in commercial tablets in comparison to the routine normal-phase HPTLC method. The greenness index for both methods was assessed using “Analytical GREENness (AGREE)” methodology. GFT detection was carried out using both methods at 332.0 nm. In the 30–700 ng/band and 20–1400 ng/band ranges, the routine and greener HPTLC assays were linear for GFT estimation. The greener HPTLC method was highly sensitive, more accurate, more precise, and more robust than the routine HPTLC assay for GFT estimation. Both methods were able to detect GFT in the presence of its degradation products, suggesting the stability-indicating property of both methods. The assay of GFT in commercial tablets was 92.45% and 99.74% using the routine and greener HPTLC assays, respectively. The AGREE index for routine and greener analytical assays was predicted to be 0.44 and 0.77, respectively, indicating the excellent greenness index of the greener HPTLC assay over the routine HPTLC assay. The greener HPTLC assay is considered superior to the routine HPTLC assay based on these results.
Trastuzumab is a target-based recombinant humanized IgG1 monoclonal antibody (mAbs), extensively employed for treatment of metastatic breast cancer with human epidermal growth receptor 2 (HER2) overexpression. Studies around the world have reported that mAbs have substantial inter-patient unpredictable absorption, distribution, metabolism, and excretion (ADME-pharmacokinetics) because of multiple elements manipulating the concentration of mAbs in plasma. Herein, we have established a bioanalytical technique using UPLC-MS/MS with an easy sample workup method and in-solution digestion protocol to assay the trastuzumab plasma samples from breast cancer patients in clinical studies. Surrogated proteolytic peptides were used for accurate quantification of trastuzumab (CanMab) with a trastuzumab signature peptide with [13C6, 15N4]-arginine and [13C6, 15N2]-lysine stable isotope-labeled (SIL) peptide. Experiments to validate the method were accurately carried out according to the guidelines mentioned in the bioanalytical method validation protocol. The evaluation established excellent linearity over a wide range of 5–500 µg/mL. The experimental procedure was efficaciously performed in a pilot study of five breast cancer patients and residual concentrations of drugs from responding and non-responding subjects were compared. The receiver operating characteristic (ROC) examination displayed that 52.25 µg/mL was the Cmin threshold predictive response with a satisfactory sensitivity of 88.58% and specificity of 79.25%.
trastuzumabplasma drug quantificationbreast cancerHER2-positive metastatic breast cancer