National Trends and Disparities in Congenital Heart Disease Mortality in the United States, 1999–2024
Pediatric Cardiology · مجلد 47 (8) · 3520-3531
Research outputs
مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.
3 مُخرَج نتائج البحث عن «Cardiology»
Pediatric Cardiology · مجلد 47 (8) · 3520-3531
Cardiology in Review
Sodium-glucose cotransporter-2 (SGLT2) inhibitors are a cornerstone of adult heart failure (HF) therapy and are increasingly prescribed off-label to children, yet pediatric outcomes have never been pooled. We searched PubMed/MEDLINE, Embase, Scopus, and Web of Science to 14 August 2026 for studies of any SGLT2 inhibitor in children or adolescents with HF and performed a single-arm meta-analysis of all exposed patients and a pairwise meta-analysis of the comparative studies with random-effects models. Nine studies contributed 599 exposed patients and 97 controls. Pooled rates were 3.8% (95% confidence interval [CI] 1.6-8.4) for mortality, 8.5% (6.2-11.5) for transplantation, 11.2% (8.2-15.1) for worsening HF, 0.2% (0.03-1.6) for ketoacidosis, 4.5% (1.2-14.9) for acute kidney injury, 3.7% (1.1-11.7) for urinary tract infection, and 4.1% (1.4-11.2) for discontinuation because of an adverse event. After initiation, left ventricular ejection fraction rose by 7.7 percentage points (3.6-11.8) and natriuretic peptide fell by 0.42 standard deviations (0.34-0.49). In the comparative synthesis (63 exposed, 97 unexposed), risk ratios were 0.80 (0.11-6.07) for mortality and 0.21 (0.03-1.68) for worsening HF; ejection fraction improved 3.34 percentage points more with SGLT2 inhibitors (0.22-6.46) whereas natriuretic peptide did not differ (standardized mean difference -0.09, -0.50 to 0.33).
Book Publisher International (a part of SCIENCEDOMAIN International) · 193-197
Background: Public protection is greatly enhanced by the knowledge of health care practitioners. Advocates of simulation-based curriculum assert that this modality plays an especially significant role. Auscultation with stethoscope is an indispensable tool for optimal management of cardiopulmonary patients. However, the acquisition of sufficient training in cardiopulmonary auscultation is not straightforward because of the technical and ethical problems. Aims: The aim of this study is to validate a homegrown stethoscope simulator for cardiopulmonary auscultation developed by the author and claimed to be of a low-cost and high-fidelity. Materials and Methods: The hardware was built from a normal clinical stethoscope and a bluetooth headset, and the software is a single PowerPoint presentation slide with links to cardiopulmonary sounds’ audio tracts. The stethoscope simulator was verified by the inventor, and a panel of experts was asked to evaluate its value as a training tool, relevance to practice, physical attributes, realism of experience, ability to perform tasks, realism of material” and realism of auscultation sounds. The validity of this homegrown stethoscope simulator was assessed by a panel of experts. The members had a session on the simulator and how it works, allowed to physically examine the stethoscope simulator, instructed on how to use it, and then auscultated all its cardiopulmonary sounds. A survey was provided to each member of the panel, and they were asked to rate their responses using a 5-point Likert scale as follows: strongly disagree (1), disagree (2), neutral (3), agree (4), and strongly agree (5). Results: Experts in cardiology, respiratory medicine and respiratory care agreed upon the characteristics and attributes of this stethoscope simulator and the observed average of the “global assessment” of the stethoscope simulator was acceptable. The cost of fabrication of one simulator of this type was approximately 100 USD. Conclusion: Primary evidence shows that this homegrown stethoscope simulator is a valuable instrument that can be built into bedside training and clinical experience labs to help undergraduate students understand and teach cardiopulmonary auscultation.