There has been no assessment of the greenness of the described analytical techniques for the simultaneous determination (SMD) of caffeine and paracetamol. As a result, in comparison to the greener normal-phase high-performance thin-layer chromatography (HPTLC) technique, this research was conducted to develop a rapid, sensitive, and greener reversed-phase HPTLC approach for the SMD of caffeine and paracetamol in commercial formulations. The greenness of both techniques was calculated using the AGREE method. For the SMD of caffeine and paracetamol, the greener normal-phase and reversed-phase HPTLC methods were linear in the 50-500 ng/band and 25-800 ng/band ranges, respectively. For the SMD of caffeine and paracetamol, the greener reversed-phase HPTLC approach was more sensitive, accurate, precise, and robust than the greener normal-phase HPTLC technique. For the SMD of caffeine paracetamol in commercial PANEXT and SAFEXT tablets, the greener reversed-phase HPTLC technique was superior to the greener normal-phase HPTLC approach. The AGREE scores for the greener normal-phase and reversed-phase HPTLC approaches were estimated as 0.81 and 0.83, respectively, indicated excellent greenness profiles for both analytical approaches. The greener reversed-phase HPTLC approach is judged superior to the greener normal-phase HPTLC approach based on numerous validation parameters and pharmaceutical assays.
Controlled-release effervescent floating bilayer tablets reduce dosage frequency and improve patient compliance with enhanced therapeutic outcomes. Generally, two different tablets of clarithromycin and esomeprazole, respectively, are given for the treatment of Helicobacter pylori infection and it might be worth incorporating both in a single tablet. In the current study, controlled-release floating bilayer tablets of clarithromycin and esomeprazole (F1−F4) were developed with different rates of polymeric materials by a direct compression method. During the formulation, Fourier-transform infrared spectroscopy (FTIR) analysis was performed for possible interactions between drugs and excipients. No interactions between drugs and excipients were noted. Moreover, the bilayer tablets’ thickness, diameter, friability, hardness, weight variation, dissolution, and percent purity were found within the acceptable limits. The floating lag time and total floating time of all formulations were found to be < 25 s and 24 h, respectively. The release of both the clarithromycin and esomeprazole started at the same time from the controlled-release floating bilayer tablets by anomalous non-Fickian diffusion, and the polymeric materials extended the drug release rate up to 24 h. In the case of F1, the results approached ideal zero-order kinetics. The dissolution profiles of the tested and reference tablet formulations were compared, but no significant differences were observed. It can be concluded that such controlled-release effervescent floating bilayer tablets can be efficiently used in clinical practice to reduce dosage frequency and increase patient compliance with continuous drug release for 24 h, which ultimately might enhance therapeutic efficacy.
esomeprazoleclarithromycineffervescent tabletscontrolled drug release
The study aimed to develop a new reverse-phase high-performance liquid chromatography (RP-HPLC) method with diode array detection (DAD) detection for simultaneous estimation of escitalopram (EST) and clonazepam (CZP) in tablet dosage forms with a quality by design (QbD) approach. The chromatographic conditions were optimized by Box-Behnken design (BBD) and developed method was validated for the linearity, system suitability, accuracy, precision, robustness, sensitivity, and solution stability according to International Council for Harmonization (ICH) guidelines. EST and CZP standard drugs peaks were separated at retention times of 2.668 and 5.046 min by C-18 column with dimension of 4.6 × 100 mm length and particle size packing 2.5 µm. The mobile phase was methanol: 0.1% orthophosphoric acid (OPA) (25:75, v/v), with a flow rate of 0.7 mL/min at temperature of 26 °C. The sample volume injected was 20 µL and peaks were detected at 239 nm. Using the standard calibration curve, the % assay of marketed tablet was founded 98.89 and 98.76 for EST and CZP, respectively. The proposed RP-HPLC method was able to detect EST and CZP in the presence of their degradation products, indicating the stability-indicating property of the developed RP-HPLC method. The validation parameter’s results in terms of linearity, system suitability, accuracy, precision, robustness, sensitivity, and solution stability were in an acceptable range as per the ICH guidelines. The newly developed RP-HPLC method with QbD application is simple, accurate, time-saving, and economic.