High-sensitivity dual analysis of Baricitinib and remdesivir in serum and urine using HPLC-fluorescence and LC-MS approaches in COVID-19 therapy
Journal of Chromatography B · مجلد 1272 · 124927-124927
Research outputs
مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.
13 مُخرَج نتائج البحث عن «method validation»
Journal of Chromatography B · مجلد 1272 · 124927-124927
International Journal of Analytical Chemistry · مجلد 2026 (1) · 4376722-4376722
Dasatinib, a therapy for chronic myeloid leukemia, suffers from poor bioavailability. Self‐microemulsifying drug delivery systems (SMEDDSs) are used to improve its dissolution. This study aimed to develop and validate a novel reverse‐phase high‐performance liquid chromatography (RP‐HPLC) method for quantifying dasatinib in SMEDDS formulations. The RP‐HPLC method utilized a mobile phase of methanol and 0.1% trifluoroacetic acid (55:45, v/v) and identified a peak wavelength for dasatinib at 324 nm. SMEDDS formulations comprised Capryol 90, Transcutol HP, and Tween 40. The method was validated according to ICH guidelines, demonstrating excellent linearity ( R 2 = 0.9993), accuracy (recovery between 98% and 101%), and precision (relative standard deviation of 0.73%). It also showed stability and reliability with limits of detection and quantification of 0.17 and 0.50 µg/mL, respectively. This RP‐HPLC method meets all validation criteria and provides a robust, cost‐effective tool for analyzing dasatinib in SMEDDS formulations.
BMC Chemistry · مجلد 17 (1) · 137-137
Four simple, specific, easy, precise and accurate spectrophotometric methods were developed for the first time to examine ciprofloxacin and metronidazole in combination, without having been separated beforehand by the developed methods. Ciprofloxacin and metronidazole were determined by utilizing advanced absorbance subtraction (AAS), spectrum subtraction, bivariate and ratio difference methods. Precision, repeatability, robustness, and accuracy were all determined to be within acceptable levels after each of these procedures underwent validation in accordance with ICH recommendations. Each method's benefits and drawbacks are illustrated, and the proposed and reported methodologies were statistically compared.
Separations · مجلد 10 (3) · 159-159
An accurate, precise and sensitive reverse-phase high-performance liquid chromatography (RP-HPLC) bioanalytical approach was developed for the simultaneous estimation of cinnarizine (CIN) and domperidone (DOM) in rat plasma using irbesartan (IRB) as an internal standard (IS). The proposed RP-HPLC approach was validated as per the latest ICH M10 guidelines. The analytes (CIN and DOM) and IS were extracted from plasma samples using the protein precipitation strategy. Chromatographic separation is accomplished by a C18 SunfireTM (5 µm, 250 mm × 4.6 mm) analytical column, using an isocratic mobile phase consisting of acetonitrile-methanol in 30:70 proportions at a flow rate of 1 mL/min. The detection of all three constituents was recorded at a wavelength of 270 nm with a UV detector. DOM, CIN and IS were eluted at 3.2, 4.5 and 6.1 min, respectively, utilizing a total run time of 10 min. The lower limit of quantification (LLOQ) was 5 ng/mL for CIN and DOM in rat plasma. The proposed RP-HPLC approach was linear in the 5–200 ng/mL range for CIN and DOM. The recovery of the method was greater than 95%, and the relative uncertainty was less than 2%, indicating that the proposed bioanalytical approach was accurate and precise. The limit of detection was established as 1.1 ng/mL for CIN and 1.7 ng/mL for DOM. The created approach was found to be robust and passed all validation criteria; thus, the proposed RP-HPLC approach can be employed successfully for the simultaneous assessment of CIN and DOM in rat plasma.
Processes · مجلد 10 (6) · 1082-1082
Thymoquinone (THY) is a bioactive compound present in the seed powder of Nigella sativa (NS). This research aims to precisely and accurately estimate THY using high-performance liquid chromatography (HPLC) with a Quality by Design (QbD) application. Box-Behnken design (BBD) was employed to optimize the chromatographic conditions for HPLC method development, taking mobile phase flow rate, pH of the buffer, and λmax as independent variables and retention time and tailing factor as the measured responses. The mobile phase composition was methanol: acetonitrile: buffer (2.2 mM ammonium formate) at the ratio of 35:50:15 v/v/v on a Symmetry® C18 (5 μm, 3.9 × 150 mm) column. In isocratic mode, it had a flow rate 0.9 mL min−1 and eluted analyte was detected at 249 nm. Validation parameters followed the International Council for Harmonization (ICH) guidelines for the new HPLC method. The method was linear over the range 6.25–100 µg mL−1 with a coefficient of determination (r2) of 0.9957. The limit of detection (LOD) and limit of quantification (LOQ) were 2.05 and 6.25 µg mL−1, respectively. The %RSD of system suitability for retention time was 1.42% and for the tailing factor it was 0.695%. In addition, the developed method was precise, accurate, and robust according to ICH criteria. The developed HPLC method is simple, accurate, quick, and robust, and it could be used for the routine analysis of THY in different kinds of formulations.
Molecules · مجلد 27 (2) · 405-405
There has been no assessment of the greenness of the described analytical techniques for the simultaneous determination (SMD) of caffeine and paracetamol. As a result, in comparison to the greener normal-phase high-performance thin-layer chromatography (HPTLC) technique, this research was conducted to develop a rapid, sensitive, and greener reversed-phase HPTLC approach for the SMD of caffeine and paracetamol in commercial formulations. The greenness of both techniques was calculated using the AGREE method. For the SMD of caffeine and paracetamol, the greener normal-phase and reversed-phase HPTLC methods were linear in the 50-500 ng/band and 25-800 ng/band ranges, respectively. For the SMD of caffeine and paracetamol, the greener reversed-phase HPTLC approach was more sensitive, accurate, precise, and robust than the greener normal-phase HPTLC technique. For the SMD of caffeine paracetamol in commercial PANEXT and SAFEXT tablets, the greener reversed-phase HPTLC technique was superior to the greener normal-phase HPTLC approach. The AGREE scores for the greener normal-phase and reversed-phase HPTLC approaches were estimated as 0.81 and 0.83, respectively, indicated excellent greenness profiles for both analytical approaches. The greener reversed-phase HPTLC approach is judged superior to the greener normal-phase HPTLC approach based on numerous validation parameters and pharmaceutical assays.
Molecules · مجلد 27 (19) · 6761-6761
Common methodologies such as liquid-liquid extraction and solid-phase extraction are applied for the extraction of opioids from biological specimens i.e., blood and urine. Techniques including LC-MS/LC-MSMS, GC-MS, etc. are used for qualitative or quantitative determination of opioids. The goal of the present work is to design a green, economic, rugged, and simple extraction technique for famous opioids in human blood and urine and their simultaneous quantification by GC-MS equipped with an inert plus electron impact (EI) ionization source at SIM mode to produce reproducible and efficient results. Morphine, codeine, 6-acetylmorphine, nalbuphine, tramadol and dextromethorphan were selected as target opioids. Anhydrous Epsom salt was applied for dSPE of opioids from blood and urine into acetonitrile extraction solvent with the addition of sodium phosphate buffer (pH 6) and n-hexane was added to remove non-polar interfering species from samples. BSTFA was used as a derivatizing agent for GC-MS. Following method validation, the LOD/LLOQ and ULOQ were determined for morphine, codeine, nal-buphine, tramadol, and dextromethorphan at 10 ng/mL and 1500 ng/mL, respectively, while the LOD/LLOQ and ULOQ were determined for 6-acetylmorphine at 5 ng/mL and 150 ng/mL, respectively. This method was applied to real blood and urine samples of opioid abusers and the results were found to be reproducible with true quantification.
Sustainable Chemistry and Pharmacy · مجلد 26 · 100648-100648
Microchemical Journal · مجلد 183 · 108058-108058
Agronomy · مجلد 12 (5) · 1016-1016
Greener analytical methodologies for the estimation of ascorbic acid (AA) are poorly reported in the literature. Furthermore, the green indexes of the literature’s analytical assays of AA estimation have not been assessed. As a consequence, the aim of this research is to invent and validate a simple, cost-effective, and green reverse-phase “high-performance thin-layer chromatography (HPTLC)” method for the estimating AA in the solvent extracts (SE) and ultrasound-assisted extracts (UAE) of Phyllanthus emblica, Psidium guajava, and Capsicum annuum. The greener mobile phase for AA estimation was a binary mixture of water and ethanol (70:30, v/v). At a wavelength of 265 nm, the detection of AA was carried out. The greener HPTLC technique was linear in the 25–1200 ng/band range. In addition, the method was simple, cost-effective, accurate, precise, robust, sensitive, and green. The amount of AA was highest in the SE and UAE of P. emblica compared to the SE and UAE of P. guajava and C. annuum. The amount of AA in the SE of P. emblica, P. guajava, and C. annuum was found to be 491.16, 168.91, and 144.30 mg/100 g, respectively. However, the amount of AA in the UAE of P. emblica, P. guajava, and C. annuum was found to be 673.02, 218.71, and 199.30 mg/100 g, respectively. Using the “analytical GREEnness (AGREE)” methodology, the greenness index for the developed method was calculated to be 0.88, showing that the developed method has an excellent green profile. When it came to extracting AA, the UAE method outperformed the SE method. These findings suggested that the developed method might be used to estimate the AA in a variety of vegetable crops, plant-based extracts, and commercial formulations. Furthermore, because of the use of greener solvent systems against the commonly utilized hazardous solvent systems for AA determination, this technique is also safe and sustainable.
Processes · مجلد 10 (4) · 762-762
“High-performance thin-layer chromatography (HPTLC)” methods for gefitinib (GFT) estimation are scarce in the literature. In addition, greener analytical techniques for GFT estimation are also lacking in the literature. Accordingly, an attempt was undertaken to invent and validate a sensitive and greener normal-phase HPTLC method for GFT analysis in commercial tablets in comparison to the routine normal-phase HPTLC method. The greenness index for both methods was assessed using “Analytical GREENness (AGREE)” methodology. GFT detection was carried out using both methods at 332.0 nm. In the 30–700 ng/band and 20–1400 ng/band ranges, the routine and greener HPTLC assays were linear for GFT estimation. The greener HPTLC method was highly sensitive, more accurate, more precise, and more robust than the routine HPTLC assay for GFT estimation. Both methods were able to detect GFT in the presence of its degradation products, suggesting the stability-indicating property of both methods. The assay of GFT in commercial tablets was 92.45% and 99.74% using the routine and greener HPTLC assays, respectively. The AGREE index for routine and greener analytical assays was predicted to be 0.44 and 0.77, respectively, indicating the excellent greenness index of the greener HPTLC assay over the routine HPTLC assay. The greener HPTLC assay is considered superior to the routine HPTLC assay based on these results.
Processes · مجلد 10 (3) · 509-509
Trastuzumab is a target-based recombinant humanized IgG1 monoclonal antibody (mAbs), extensively employed for treatment of metastatic breast cancer with human epidermal growth receptor 2 (HER2) overexpression. Studies around the world have reported that mAbs have substantial inter-patient unpredictable absorption, distribution, metabolism, and excretion (ADME-pharmacokinetics) because of multiple elements manipulating the concentration of mAbs in plasma. Herein, we have established a bioanalytical technique using UPLC-MS/MS with an easy sample workup method and in-solution digestion protocol to assay the trastuzumab plasma samples from breast cancer patients in clinical studies. Surrogated proteolytic peptides were used for accurate quantification of trastuzumab (CanMab) with a trastuzumab signature peptide with [13C6, 15N4]-arginine and [13C6, 15N2]-lysine stable isotope-labeled (SIL) peptide. Experiments to validate the method were accurately carried out according to the guidelines mentioned in the bioanalytical method validation protocol. The evaluation established excellent linearity over a wide range of 5–500 µg/mL. The experimental procedure was efficaciously performed in a pilot study of five breast cancer patients and residual concentrations of drugs from responding and non-responding subjects were compared. The receiver operating characteristic (ROC) examination displayed that 52.25 µg/mL was the Cmin threshold predictive response with a satisfactory sensitivity of 88.58% and specificity of 79.25%.
Separations · مجلد 8 (10) · 184-184
The rapid, highly-sensitive and ecologically greener reversed-phase (RP)/normal-phase (NP) high-performance thin-layer chromatography (HPTLC) densitometric technique has been developed and validated for the determination of trans-resveratrol (TRV). The reversed-phase HPTLC-based analysis of TRV was performed using ethanol–water (65:35, v v−1) combination as the greener mobile phase, while, the normal-phase HPTLC-based estimation of TRV was performed using chloroform–methanol (85:15, v v−1) combination as the routine mobile phase. The TRV detection was carried out at 302 nm for RP/NP densitometric assay. The linearity was recorded as 10–1200 and 30–400 ng band−1 for RP and NP HPTLC techniques, respectively. The RP densitometric assay was observed as highly-sensitive, accurate, precise and robust for TRV detection in comparison with the NP densitometric assay. The contents of TRV in commercial formulation were recorded as 101.21% utilizing the RP densitometric assay, while, the contents of TRV in commercial formulation were found to be 91.64% utilizing the NP densitometric assay. The greener profile of RP/NP technique was obtained using the analytical GREEnness (AGREE) approach. The AGREE scales for RP and NP densitometric assays were estimated 0.75 and 0.48, respectively. The recorded AGREE scale for the RP densitometric assay indicated that this technique was highly green/the ecologically greener compared to the NP densitometric assay. After successful optimization of analytical conditions, validation parameters, AGREE scale and chromatography performance, the RP densitometric assay with univariate calibration was found to be better than the NP densitometric assay for the analysis of TRV.