جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.
MF

Muhammad Fareed

بانتظار توثيق الانتساب2022–2025
41وثائق Scopus
489استشهاداً
15مؤشر h
1منها بانتماء الجامعة
إجمالي Scopus (كل الجهات)ملف الباحث في Scopus ↗آخر تحديث: 2026-11-09

كل وثائق Scopus للباحث

41
مقالوصول مفتوح20254استشهاد· Semantic Scholar

Finite element study of the efficacy of three different loops for bodily protraction of the mandibular molar

Scientific Reports · مجلد 15 (1) · 13938-13938

This study aimed to compare three different loops (T loop, Cherry loop, and Open helical loop) and optimal tip back angle (10°, 15°, 20°) for protraction of mandibular second molar using Finite Element Model (FEM). A CBCT scan of a 20-year-old patient was recorded. It was converted into a CAD file and then into a FEM. A FEM model developed was used to find out the efficacy of the loops and optimal tip-back angles. Displacement of the molar was measured at four reference points: the mesio-buccal cusp, distobuccal cusp, mesial root, and the distal root of the first molar. No significant difference was seen in the displacement for all three loops. At a 10° angle, there was more mesial tipping (5.9°) and molar extrusion. At a 15° angle, there was less mesial tipping (2.9-3°) and no changes in the vertical plane. At a 20° angle, there was bodily movement and intrusion of molars. All three loops are equally effective in the protraction of mandibular molar. A 15° tip back angle was most effective in protracting the mandibular molar as only a negligible amount of mesial tipping of the molar was seen, and there was no extrusion or intrusion of the molar, thus maintaining the occlusal plane. Loop mechanics are preferred over the use of power chains as this helps maintain better control over the molar position during protraction. Loops are very effective at avoiding mesial tipping and extrusion of molars during mesialization to close spaces.

T-loopmesial tippingmolar extrusionmolar intrusion
مقالوصول مغلق20252استشهاد· Semantic Scholar

Assessment of microstructure, microbial count with adherence and ion leaching of calcium hydroxide filled SPRG restorative material: A SEM and confocal analysis

Medical Engineering & Physics · مجلد 146 (1) · 104438-104438

AIM: This study investigates the characterization of a calcium hydroxide-filled SPRG (Surface Pre-Reacted Glass Ionomer) restorative material. The analysis focuses on the material's microstructure and antimicrobial properties, specifically its efficacy against Streptococcus mutans, a common oral bacterium. Using Scanning Electron Microscopy (SEM) and confocal microscopy, we examine the material's surface morphology, microbial adherence, and ion leaching capabilities. The goal is to assess the material's suitability for deep caries management and its potential as a dentine replacement. METHODS AND MATERIALS: Discs of Calcium Hydroxide filled SPRG Restorative Material were prepared (10 mm x 2 mm). SEM was employed to observe the surface morphology and microstructural characteristics of the material. To evaluate microbial adherence and count, confocal microscopy was used with Streptococcus mutans cultured on the material. The leaching of calcium and fluoride ions was quantified using the Ion Selective Electrode (ISE) method. RESULTS: The results showed significant leaching of calcium and fluoride ions, indicating the material's potential for ion release. SEM analysis provided detailed insights into the microstructure of the SPRG restorative material, while confocal microscopy revealed a clear distinction between live and dead Streptococcus mutans colonies, suggesting that the fluoride and calcium ion leaching contributed to effective antimicrobial properties. CONCLUSION: Calcium hydroxide-filled SPRG restorative materials show promise for dental applications, with ion release and effective antimicrobial properties making them strong candidates for managing deep caries and potentially replacing dentine. Ongoing research could optimize these materials for clinical use, advancing restorative dentistry.

calcium hydroxideS-PRGdental restorative materialsStreptococcus mutans
مقالوصول مفتوح20251استشهاد· Semantic Scholar

Role of placental extracts in enhancing periodontal flap surgery healing: insights from periostin biomarker analysis

European journal of medical research · مجلد 30 (1) · 623-623

BACKGROUND: The elimination of the causative agent and the facilitation of tissue regeneration are the fundamental objectives of periodontal therapy. Various adjunctive agents have been investigated to optimize treatment outcomes with surgical interventions. Periostin is a matricellular protein predominantly expressed in periodontal tissues, playing a key role in tissue remodeling, inflammation, and wound healing. The human placental extract has been used in periodontal surgery and compared with open flap debridement alone, with gingival crevicular fluid (GCF) periostin levels assessed to gauge periodontal wound healing. METHODS: Sixteen systemically healthy patients diagnosed with Stage III Grade C periodontitis were enrolled in the study. Participants were randomly assigned to either the test group (n = 8) or the control group (n = 8), with a total of nine males and seven females distributed across the groups. The test group underwent open flap debridement (OFD), followed by applying human placental extract gel absorbed into a gelatin sponge, while the control group received only OFD. Clinical parameters were assessed at baseline and 3 month post-treatment. GCF periostin levels were measured at baseline, 6 weeks, and 3 months. RESULTS: The test group demonstrated a mean probing pocket depth (PPD) reduction of 4.75 ± 1.28 mm, compared to 3.12 ± 1.12 mm in the control group, with the difference being statistically significant. The relative attachment level (RAL) gain was 4.37 ± 1.18 mm in the test group and 2.75 ± 0.70 mm in the control group; however, this difference was not statistically significant. At 3 months, the mean healing index score was 4.50 ± 0.53 in the test group and 3.62 ± 0.51 in the control group, with a statistically significant intergroup difference. The Plaque Index (PI), Gingival Index (GI), and Gingival Bleeding Index (BI) showed moderate reductions at 3 months; however, intergroup differences were not statistically significant, except for BI, where the difference at 3 months was -0.180. CONCLUSIONS: The adjunctive use of placental extract gel in surgical periodontal therapy demonstrated beneficial effects on healing outcomes. In addition, periostin shows promise as a biomarker for periodontal wound healing.

human placental extractperiodontal flap surgeryperiostinperiodontal healing
مقالوصول مفتوح20251استشهاد· Semantic Scholar

Scanning Electron Microscopy analysis concerning the effect of 980 nm Diode Laser and Twin Kleen irrigant for the elimination of smear layer off the root canal wall

BMC Oral Health · مجلد 25 (1) · 245-245

OBJECTIVE: The present research aims to examine the effectiveness of 980 nm Diode Laser and Twin Kleen irrigant individually in addition to the combo for removing the smear layer from tooth canals in single-rooted teeth. MATERIALS AND METHODS: 60 single-rooted mandibular premolar teeth were chosen and inspected clinically and by radiography. Protaper was employed to prepare teeth up to F4. Irrigation with 5.25% sodium hypochlorite followed each consecutive instrument. The collected, prepared teeth were distributed at random to four distinct groups of fifteen teeth each: (a) Group I: Normal saline; (b) Group II: Twin Kleen; (c) Group III: Diode Laser; (d) Group IV: Diode Laser in combo with Twin Kleen. Scanning Electron Microscope evaluation was performed. The topography of the surfaces of the 4 groups was studied, and the results were photographed. Microscopy images captured under 1000x. Using the Guttman grading methodology, the smear layer scores have been determined in the cervical, mid and apical root areas. RESULTS: Smear layer removal scores in the cervical area were least in Group III and highest in Group I. Smear layer removal scores in the middle area were least in Group III and highest in Group I. Smear layer removal scores in the apical area were least in Group IV and highest in Group I. CONCLUSION: It is determined that the diode laser, in combination with Twin Kleen, improves smear layer elimination, particularly from the apical region. 980 nm diode laser can be employed as an irrigant activating technique that allows for improved absorption into restricted root canal locations.

980 nm diode lasersmear layer removalroot canal irrigationsingle-rooted mandibular premolars
مقالوصول مفتوح202214استشهاد· Semantic Scholar

Folate-Modified Chitosan 5-Flourouraci Nanoparticles-Embedded Calcium Alginate Beads for Colon Targeted Delivery

Pharmaceutics · مجلد 14 (7) · 1366-1366

Gel beads are formed when alginate acid reacts with divalent cations, particularly Ca2+. As a result of this feature, it is one of the best materials for making gel beads. Furthermore, it swells only slightly at acidic pH, resulting in stable alginate acid beads, but swells and dissolves rapidly at higher pH values, leading to pH-responsive release. Our current study aimed to embed folate-modified chitosan 5FU nanoparticles (FA-CS-5FU-NPs) into calcium alginate beads for colon-targeted delivery. Calcium alginate beads were developed successfully. Based on the method of drying, two types of beads were obtained: freeze-dried folate-modified chitosan 5FU nanoparticles-embedded beads (FA-CS-5FU-NP-Bf) and oven-dried folate-modified chitosan 5FU nanoparticles-embedded beads (FA-CS-5FU-NP-Bo). The size of (FA-CS-5FU-NP-Bf) was significantly larger than (FA-CS-5FU-NP-Bo). Swelling index (SI), erosion index (EI), and water-uptake index (WUI) of (FA-CS-5FU-NP-Bf) beads were significantly higher than FA-CS-5FU-NP-Bo beads at simulated intestinal pH. An insignificant difference was observed in the release rate of 5FU between (FA-CS-5FU-NP-Bf) and FA-CS-5FU-NP-Bo. The release rate of FA-CS-5FU-NPs was significantly higher than FA-CS-5FU-NP-Bf and FA-CS-5FU-NP-Bo. Pharmacokinetic parameters of 5FU solution, FA-CS-5FU-NPs, and FA-CS-5FU-NP-Bo were analyzed. Solution of pure 5FU showed significantly higher Cmax and lower AUC, T1/2, and Vd than both FA-CS-5FU-NPs and FA-CS-5FU-NPs-Bo, suggesting that FA-CS-5FU-NPs and FA-CS-5FU-NPs-Bo have sustained-release behavior. Biodistribution studies also show that maximum drug amounts were found in the colon from nanoparticles-embedded beads. FA-CS-5FU-NPs-Bo avoid releasing drugs in the stomach and small intestine and make them available in the colon region in higher concentrations to target the colon region specifically.

5-fluorouracilcalcium alginate beadscolon-targeted drug deliverypH-responsive drug release